Hi Lynn,

We are Magic 5.5SR1 and have the Architect ci8200.  Our QC crosses based on QC mnemonic rather than barcode.

 

Good luck!  Brenda

 

Brenda Garris, MT(ASCP)

LIS Manager

Arlington Memorial Hospital Laboratory

Arlington, Texas

817-548-6243

 

 

Date: Sat, 2 Sep 2006 15:33:29 -0400

From: Patti Lawing <[EMAIL PROTECTED]>

Subject: [MEDITECH-L] Message: 3

Date: Sat, 2 Sep 2006 15:33:29 -0400

From: Patti Lawing <[EMAIL PROTECTED]>

Subject: [MEDITECH-L] Lab Question

To: "'[email protected]'" <[email protected]>

Message-ID:

      <871701CECE[EMAIL PROTECTED]>

     

Content-Type: text/plain

 

 

 

Is there anyone who is running a Laboratory interface for the Abbott Architect i2000SR with Meditech who could answer a question about how you set up QC?

 

We are trying to run barcoded controls at the Architect (same barcode defined at both analyzer system config and in Meditech Std/Control & Analyzer type dictionaries) and have the specimens go across the interface, and Meditech create QC specimens based on the bar code number recognition and the tests being sent.  This is how our B-C Chemistry analyzer interfaces work, but we can't seem to get this to happen with the i2000 interface.  Any suggestions?

 

 

 

 

thanks

 

Lynn Reinhardt, MT(ASCP)

Lab/LIS Manager

Rutherford Hospital, Inc.

Rutherfordton, NC

[EMAIL PROTECTED]

(828)286-5123

To: "'[email protected]'" <[email protected]>

Message-ID:

      <871701CECE[EMAIL PROTECTED]>

     

Content-Type: text/plain

 

 

 

Is there anyone who is running a Laboratory interface for the Abbott Architect i2000SR with Meditech who could answer a question about how you set up QC?

 

We are trying to run barcoded controls at the Architect (same barcode defined at both analyzer system config and in Meditech Std/Control & Analyzer type dictionaries) and have the specimens go across the interface, and Meditech create QC specimens based on the bar code number recognition and the tests being sent.  This is how our B-C Chemistry analyzer interfaces work, but we can't seem to get this to happen with the i2000 interface.  Any suggestions?

 

 thanks

 

Lynn Reinhardt, MT(ASCP)

Lab/LIS Manager

Rutherford Hospital, Inc.

Rutherfordton, NC

[EMAIL PROTECTED]

(828)286-5123

 

 


The information contained in this message and any attachments is intended only for the use of the individual or entity to which it is addressed, and may contain information that is PRIVILEGED, CONFIDENTIAL, and exempt from disclosure under applicable law. If you are not the intended recipient, you are prohibited from copying, distributing, or using the information. Please contact the sender immediately by return e-mail and delete the original message from your system.