I wanted to post to the "L" the issues that we had with this enhancement. First of all, I couldn't get our labels to print the barcode #...they kept printing a "1". Meditech was no help for this. The task went back and forth between us. I played with it for a bit and realized that I couldn't have the keyword in a "lbl combination" type. So I changed this an used it alone on the label and whoa!, it finally printed the barcode correctly. You also must have the "lsp sample type" keyword somewhere on the label. I put this after the barcode number on ours and it is fine. It took seven months of going back and forth with my specialist to actually get this working. Hopefully I can spare someone else the pain! Now that we have it working, we love it!
Dianna Harrington MIS Department Clinical Systems Analyst The William W. Backus Hospital Norwich, CT 06360 ________________________________ From: [email protected] [mailto:[EMAIL PROTECTED] On Behalf Of Brick, Julie C. Sent: Wednesday, May 09, 2007 1:00 PM To: [email protected] Subject: [MEDITECH-L] Sample type enhancement in LAB Is anyone using the sample types for containers in LAB to generate different bar code labels for different sample types per specimen? If so, does it work well for your lab? In reading the DTS which introduced this functionality, it seems to me it has just made specimen tracking and processing more complicated. Are you able to tell visually from the label that this bar code for the red tube only contains the tests which require a red tube and not a green tube test that has combined to the same specimen because they are in the same department? Does anyone else think it would make more sense to generated different specimen numbers if the tests have different collection containers but are in the same department? Julie Brick, MT(ASCP) LIS Coordinator Anne Arundel Medical Center 443-481-4270 [EMAIL PROTECTED] <mailto:[EMAIL PROTECTED]> ________________________________ This message [including any attachments] contains information intended for a specific individual[s] and purpose that may be confidential or otherwise legally protected from disclosure. Any review, use, distribution, disclosure of contents, or copying of the message is strictly prohibited. If you have received this transmission in error, please reply to the sender indicating this error and delete the transmission from your system immediately without copying or disclosing the information. ******************************************************************************************************************* Personal Data - Privacy Act of 1974 (PL 93-579) This transmission is intended to be confidential to the individual(s) and/ or entity to whom addressed. It may contain information of a privileged and/or confidential nature, which may be subject to protection under the Privacy Act of 1974 and the Health Insurance Portability and Accountability Act (HIPAA) of 1996. In the event you are not the intended recipient or the agent of the intended recipient, or you are unable to deliver this communication to the intended recipient, do not read, copy, or use this information contained within this transmission, or allow it to be read, copied or utilized in any manner, by any other person(s). Should this transmission be received in error or there is a problem with the transmission, please notify the above named sender immediately at the telephone number provided The William W. Backus Hospital 326 Washington St Norwich CT 06360 860 889-8331 *******************************************************************************************************************
=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*= To subscribe or unsubscribe to the meditech-l, visit MTUsers.NET. To check the status of the meditech-l, visit MTUsers.NET. For help, email [EMAIL PROTECTED] Visit the MTUsers WikiPedia at MTUsers.NET/mwiki ______________________________________ meditech-l mailing list [email protected] http://mtusers.com/mailman/listinfo/meditech-l