On Wed, 25 Dec 2019 04:37:07 +0000 (UTC) Max Dillon <dillonm...@gmail.com> wrote:
> > The SPDT function seems to be done mechanically in the base. I haven't > taken one apart yet, but I surmise that the solenoid moves a rod that > has two valve seats, which are opposed so that only one can be open at > a time. You missed my point: From what I have seen, the monovalve has one inlet and one outlet. There is no way for it to do an SPDT function. > The part is the entire assembly. Only the circulation pump is available > as a separate part. That's why it's so expensive, as I suspected! Craig _______________________________________ http://www.okiebenz.com To search list archives http://www.okiebenz.com/archive/ To Unsubscribe or change delivery options go to: http://mail.okiebenz.com/mailman/listinfo/mercedes_okiebenz.com