Joe, Check to see if both machines had the same make and model tape reader. There were many different tape reader configurations, and the Fanuc's tape input port could be configured to match different types. If yours were different, then this is a place to start.
Both the control and the BTR should be adaptable. If you're keeping the tape reader, then you must change the BTR to match it. If not, then you can change that control's parameters to match the other control. Gene Bowen > All: > > Has anyone out there ever encountered this problem? I am hooking up > some DNC stations to a pair of Matsuura vertical machining centers with > FANUC 5M controls. Because of their age, there is no serial > communications ports on them, so input must be thru a parallel BTR. I > have gotten one of the pair to function, but the other refuses to > recognise the file being downloaded ====================================================================== To find out more about this mailing list including how to unsubscribe, send the message "info mfg-smartcam" to [EMAIL PROTECTED] ======================================================================