Is the Z1.0 hard coded in you tmp file?  Are you using it as a clearance 
 value?   If you are you could replace it with Z#CLEAR or maybe Z#POS  then 
in your pm4 file assign whatever clearance value you want.

Line out of my tmp file.
G43 H#LOFF Z#ZPOS #COOLNT


John


-----Original Message-----
From:   Colin Williams [SMTP:[EMAIL PROTECTED]]
Sent:   Wednesday, June 14, 2000 2:55 PM
To:     Smartcam Forum
Subject:        [mfg-smartcam] G43 LINE

 << File: ATT00000.html >> In my "G43 Z1.0 H01" line I usually have a "Z" 
value of 1.0. How do I change this value just for one tool (Z1.25)  then go 
back to "Z1.0" for the next tool.



Thank You

Colin Williams




======================================================================
To find out more about this mailing list including how to unsubscribe,
send the message "info mfg-smartcam" to [EMAIL PROTECTED]
======================================================================

Reply via email to