Chris, First check in the "Planner" section of your application ini (i.e. ffm.ini) file for the path to the "StepListFormatFile". [Planner] StepListFormatFile=C:\Sm9\mill\josdef\MSTEPLST.FMT Then make sure the file in that path exists. If it does, it may have been corrupted. There is usually a backup file "MSTEPLST.OLD" that you can copy and then change the "OLD" extension to "FMT". Otherwise I have attached a copy of my default step list format file you can try. NOTE: You may encounter additional error messages after you address this one, depends on the condition of the other support files.
============================================= Fred Lauzus, CAM Programming Coordinator High Steel Structures, Incorporated mailto:[EMAIL PROTECTED] <mailto:[EMAIL PROTECTED]> http://www.highsteel.com <http://www.highsteel.com/> ============================================= -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]] Sent: Wednesday, August 21, 2002 5:17 PM To: [EMAIL PROTECTED] Subject: [mfg-smartcam] Error 10010: cannot start SmartCam Importance: High Hi all, We had a brown out here at work, and since then SmartCam will not run on one of our pc's. Everything else on this pc works fine. When I try to start SmartCam, I get the following error: 10010: The Step List Format File has a fatal error in it. Cannot continue. I backed up my smartcam.ini & pmill.ini files and tried re-installing the software, to no avail. I then deleted the Josdef folder, tried re-installing the software again, and still had no success. Any ideas? Chris <mailto:[EMAIL PROTECTED]> Kocourek Tool Design Engineer Flextronics Thanks Jeff for the signature!