In your template file.  Take the conditional brackets (<>) off the "Q".

example:
Before--
< #ABSI>< G83>< #RTNLVL> X#XPOS Y#YPOS < Z#ZDPTH>< R#ZCHK>< Q#PECK><F#FEED>

After --
< #ABSI>< G83>< #RTNLVL> X#XPOS Y#YPOS < Z#ZDPTH>< R#ZCHK> Q#PECK<F#FEED>

John
-----Original Message-----
From: Chad Seelbinder [mailto:[EMAIL PROTECTED]
Sent: Wednesday, March 03, 2004 11:08 AM
To: [EMAIL PROTECTED]
Subject: [mfg-smartcam] mfg-smartcam


       I have a really simple problem that I hope there will be an easy
answer for. When I code out a peck drilling cycle (G83) I have a default
peck value of .100 (Q0.100). the problem is when I go to the next hole, It
leaves the peck value out, and my controller doesn't see it as the default.
Is there any way to make it code out the q value every time, even if is the
same as the last time???
I tried to change smf question #5 to #2 and it didn't work. Any ideas?????

Thank You
Chad Seelbinder


BETTER WIRE PRODUCTS INC.
1255 NIAGARA STREET
BUFFALO, NEW YORK 14213
PHN#716-883-3377 FAX#716-883-5075

DEDICATED TO SUPERIOR QUALITY AND SATISFACTION


======================================================================
To find out more about this mailing list including how to unsubscribe,
send the message "info mfg-smartcam" to [EMAIL PROTECTED]
======================================================================