Hello,
to suppress the pid change warning, you can use alert filter like this:
set alert user@domain but not on { pid, ppid }
Regards,
Martin
On Apr 26, 2012, at 4:07 PM, Alexandre Carlos Vilarinho de Oliveira wrote:
> Hello all,
>
> Recently I´ve started to monitor CACTI with Monit, but because of cacti’s
> nature it do run constantly and every time it restart a new PID is used, and
> because of it Monit keeps changing the status of the process instead of
> keeping it ok. Is it possible to avoid this behavior?
>
> How can I monitor CACTI and avoid Monit to flood e-mails of PID changes?
>
> Regards
>
>
> Atenciosamente
>
> Alexandre Vilarinho
> Gerente de Engenharia de Rede IP/TI
> Tel.: (55 11) 3017-4683
> Cel.: (55 11) 7757-8388
> Fax: (55 11) 3017-4464
> [email protected]
> www.neovia.com.br
> ----------------------------
>
>
>
> --