Hi, you can point to the previous configuration file with the old weights:
[TUNING] ### instead of tuning with this setting, old weights may be recycled # specify here an old configuration file with matching weights # weight-config = $toy-data/weight.ini -phi On Wed, May 20, 2015 at 3:01 PM, Lane Schwartz <[email protected]> wrote: > I've got a system that I trained using EMS. I'd like to change the > binarization of my LM (for example, the original used KenLM probing, and > now I want KenLM trie with quantization). > > If I simply change the lm-binarizer line in my config, EMS assumes that it > should re-run tuning. Is there a way that I can force it to not re-tune in > this case? > > Thanks, > Lane > > > _______________________________________________ > Moses-support mailing list > [email protected] > http://mailman.mit.edu/mailman/listinfo/moses-support > >
_______________________________________________ Moses-support mailing list [email protected] http://mailman.mit.edu/mailman/listinfo/moses-support