What's the difference between what Philipp is suggesting (weight-config = ...) and what Matthias is suggesting (config-with-reused-weights = ...) ?
On Wed, May 20, 2015 at 2:14 PM, Matthias Huck <[email protected]> wrote: > Hi Lane, > > Just do the LM binarization manually, edit the LM feature line in your > tuned moses.ini to point to your new binary LM, and tell the EMS where > to look for the tuned moses.ini: > > > [TUNING] > config-with-reused-weights = $working-dir/tuning/moses.tuned.ini.10 > > > It won't run tuning if you set config-with-reused-weights. > > Cheers, > Matthias > > On Wed, 2015-05-20 at 14:01 -0500, Lane Schwartz wrote: > > I've got a system that I trained using EMS. I'd like to change the > > binarization of my LM (for example, the original used KenLM probing, and > > now I want KenLM trie with quantization). > > > > If I simply change the lm-binarizer line in my config, EMS assumes that > it > > should re-run tuning. Is there a way that I can force it to not re-tune > in > > this case? > > > > Thanks, > > Lane > > _______________________________________________ > > Moses-support mailing list > > [email protected] > > http://mailman.mit.edu/mailman/listinfo/moses-support > > > > -- > The University of Edinburgh is a charitable body, registered in > Scotland, with registration number SC005336. > > -- When a place gets crowded enough to require ID's, social collapse is not far away. It is time to go elsewhere. The best thing about space travel is that it made it possible to go elsewhere. -- R.A. Heinlein, "Time Enough For Love"