> With the 3.67 (using then DLL), when I resample 22050 to 44100, I get clicks
> too.
> The result sounds not really bad, but clicks are presents...
>
> How is it possible to correct that ?
> Thanks
Yep the clicks in 3.67 mainly come from teh cubic interpolation code which
isn't checking for overflows, that's what was causing most of my problems -
you can either hack the source to check for overflow in the resample routine,
or you can just reduce the volume fo your input file by a few percent
Scott Manley (aka Szyzyg) /------ _@/ Mail -----\
___ _ _ __ __ _ | Armagh Observatory |
/ __| __ ___| |_| |_ | \/ |__ _ _ _ | |___ _ _ | Armagh |
\__ \/ _/ _ \ _| _| | |\/| / _` | ' \| / -_) || | | Northern Ireland |
|___/\__\___/\__|\__| |_| |_\__,_|_||_|_\___|\_, | | BT61 9DG. |
http://star.arm.ac.uk/~spm/welcome.html |__/ \=====================/
--
MP3 ENCODER mailing list ( http://geek.rcc.se/mp3encoder/ )