> With the 3.67 (using then DLL), when I resample 22050 to 44100, I get clicks
> too.
> The result sounds not really bad, but clicks are presents...
> 
> How is it possible to correct that ?
> Thanks


Yep the clicks in 3.67 mainly come from teh cubic interpolation code which 
isn't checking for overflows, that's what was causing most of my problems - 
you can either hack the source to check for overflow in the resample routine, 
or you can just reduce the volume fo your input file by a few percent

Scott Manley (aka Szyzyg)                           /------ _@/ Mail -----\
 ___         _   _     __  __           _           |  Armagh Observatory |
/ __| __ ___| |_| |_  |  \/  |__ _ _ _ | |___ _  _  |  Armagh             |
\__ \/ _/ _ \  _|  _| | |\/| / _` | ' \| / -_) || | |  Northern Ireland   |
|___/\__\___/\__|\__| |_|  |_\__,_|_||_|_\___|\_, | |  BT61 9DG.          |
http://star.arm.ac.uk/~spm/welcome.html       |__/  \=====================/


--
MP3 ENCODER mailing list ( http://geek.rcc.se/mp3encoder/ )

Reply via email to