Tuesday you sent me mail regarding [rrd-developers] Re: Restarting devices:
*> > The question I initially meant to ask is still dangling: *> > The average values 5696416 and 5489639 obtained for the 500-second interval *> > just following the presumed counter reset (or even their adjusted 300-second *> > interval values, I believe) exceed the maximum value (256000) I specified for *> > the DS; why does RRDtool go through with the calculations for the next *> > interval, using these 'bad' values? Shouldn't it come up with NaN for the *> > 949002300 interval? *> > rrdtool only comes up with NaN for an interval if more than Minimal required heartbeat seconds of the interval are UNKNOWN ... the DS min/max specs are tested after each STEP interval ... it might be argued that this test should occur after each update instead ... cheers tobi -- ______ __ _ /_ __/_ / / (_) Oetiker, Timelord & SysMgr @ EE-Dept ETH-Zurich / // _ \/ _ \/ / TEL: +41(0)1-6325286 FAX:...1517 ICQ: 10419518 /_/ \.__/_.__/_/ [EMAIL PROTECTED] http://ee-staff.ethz.ch/~oetiker -- Unsubscribe mailto:[EMAIL PROTECTED] Help mailto:[EMAIL PROTECTED] Archive http://www.ee.ethz.ch/~slist/rrd-developers