Almost forgot, spend about 60 bucks and buy a Raytek MiniTemp. Good tool for spot checking anything.
Tv -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] Behalf Of Syed Ali Sent: Tuesday, March 04, 2003 11:59 AM To: [EMAIL PROTECTED] Subject: [mrtg] Re: Monitoring APC UPS temp Since we are talking about temperature, any suggestions on which place is best in a data center for temperature and humidity probes? Some options that I can think of are: 1. in front of servers (all my servers take in care from the front and push it out of the back) 2. in back of servers 3. away from the servers With #1 I can get an estimate of the temp and humidity of the air intake for the servers. With #2 I can get an estimate of the temp and humidity of the air being output by the servers. With #3 I can get an estimate of the general temp and humidity in the data center. Any thoughts? -----Original Message----- From: Jerry Heidtke [mailto:[EMAIL PROTECTED] Sent: Monday, March 03, 2003 10:17 PM To: 'Sameh Ahmed'; [EMAIL PROTECTED] Subject: [mrtg] Re: Monitoring APC UPS temp Remove the # from in front of Options[DEVICE_NAME_batt-temp]. This needs to be specified as a gauge. Otherwise, mrtg tries to calculate a rate of degrees per second, which you surely don't want. Jerry -----Original Message----- From: Sameh Ahmed [mailto:[EMAIL PROTECTED] Sent: Monday, March 03, 2003 6:52 PM To: [EMAIL PROTECTED] Subject: [mrtg] Re: Monitoring APC UPS temp Hello After lots of tries and help from lots of very nice guys, it works but with very unreal illogical result for the temperature, though the real temperature is listed when I do a ANMP walk that's my CFG # APC UPS Basic Output Status # CFGNAME : [DEVICE_NAME]_basic-out-status WorkDir: c:\mrtg-data\temp LoadMIBs: C:\mrtg-2.9.2\MIBs\apc.mib Target[DEVICE_NAME_batt-temp]: 1.3.6.1.4.1.318.1.1.1.2.2.2.0&1.3.6.1.4.1.318.1.1.1.2.2.2.0:[EMAIL PROTECTED] .0.1 .128 MaxBytes[DEVICE_NAME_batt-temp]: 100 Title[DEVICE_NAME_batt-temp]: DEVICE_NAME Battery Temperature PageTop[DEVICE_NAME_batt-temp]: <H1>DEVICE_NAME Battery Temperature</H1> #Options[DEVICE_NAME_batt-temp]: gauge, nopercent, absolute YLegend[DEVICE_NAME_batt-temp]: Temp Legend1[DEVICE_NAME_batt-temp]: Temperature Legend2[DEVICE_NAME_batt-temp]: . Legend3[DEVICE_NAME_batt-temp]: Max value per interval on graph Legend4[DEVICE_NAME_batt-temp]: . LegendI[DEVICE_NAME_batt-temp]: UPS Battery Temperature LegendO[DEVICE_NAME_batt-temp]: . these are the first few lines of the file device_name_batt-temp.log 1046730549 25 25 1046730549 0 0 0 0 1046729687 0 0 0 0 1046729400 6 6 26 26 1046729100 4 4 26 26 1046728800 0 0 0 0 1046728500 0 0 0 0 which shows that it does get the right value Any ideas? Thanks and best regards Sameh Ahmed ALS -- Unsubscribe mailto:[EMAIL PROTECTED] Archive http://www.ee.ethz.ch/~slist/mrtg FAQ http://faq.mrtg.org Homepage http://www.mrtg.org WebAdmin http://www.ee.ethz.ch/~slist/lsg2.cgi Confidentiality Notice: This e-mail message, including any attachments, is for the sole use of the intended recipient(s) and may contain confidential and privileged information. Any unauthorized review, use, disclosure or distribution is prohibited. If you are not the intended recipient, please contact the sender by reply e-mail and destroy all copies of the original message. -- Unsubscribe mailto:[EMAIL PROTECTED] Archive http://www.ee.ethz.ch/~slist/mrtg FAQ http://faq.mrtg.org Homepage http://www.mrtg.org WebAdmin http://www.ee.ethz.ch/~slist/lsg2.cgi -- Unsubscribe mailto:[EMAIL PROTECTED] Archive http://www.ee.ethz.ch/~slist/mrtg FAQ http://faq.mrtg.org Homepage http://www.mrtg.org WebAdmin http://www.ee.ethz.ch/~slist/lsg2.cgi -- Unsubscribe mailto:[EMAIL PROTECTED] Archive http://www.ee.ethz.ch/~slist/mrtg FAQ http://faq.mrtg.org Homepage http://www.mrtg.org WebAdmin http://www.ee.ethz.ch/~slist/lsg2.cgi