Hi folks,

Can you think of any reason why 64 bit counters will work great on one
router interface, but not another?

I am adding 2 interfaces together, both in and out traffic to get a TOTAL BW
graph, but it works perfect on interface 2, but I still see that counters
wrapping on 4.  The traffic volume is higher on 2 as well.

Using rateup w/mrtg v2.9.25 on win2k

This one works:
Target[working-TOTAL-AGGREGATE]: -2:[EMAIL PROTECTED]:::::2 +
-2:[EMAIL PROTECTED]:::::2 + 2:[EMAIL PROTECTED]:::::2 +
2:[EMAIL PROTECTED]:::::2
SetEnv[working-AGGREGATE]: MRTG_INT_IP="" MRTG_INT_DESCR=""
MaxBytes[working-TOTAL-AGGREGATE]: 25000000

This one still wraps:
Target[non-working_TOTAL-AGGREGATE]: -4:[EMAIL PROTECTED]:::::4 +
-4:[EMAIL PROTECTED]:::::4 + 4:[EMAIL PROTECTED]:::::4 +
4:[EMAIL PROTECTED]:::::4
SetEnv[non-working_TOTAL-AGGREGATE]: MRTG_INT_IP="" MRTG_INT_DESCR=""
MaxBytes[non-working_TOTAL-AGGREGATE]: 25000000


Thanks,
Brandon

Brandon Baker
Manager, Security & Network Services
Inforonics, Inc
Voice: (978) 698-7458
Email: [EMAIL PROTECTED]


 

--
Unsubscribe mailto:[EMAIL PROTECTED]
Archive     http://www.ee.ethz.ch/~slist/mrtg
FAQ         http://faq.mrtg.org    Homepage     http://www.mrtg.org
WebAdmin    http://www.ee.ethz.ch/~slist/lsg2.cgi

Reply via email to