I agree it is a MaxBytes issue and the data collected is larger and thus
reporting zero. I am using the default reference ($if_speed_??) for the
interface speed and this was working before. So what did or what do I need
to change in my .cfg file to allow $if_speed_?? to work? 

Options[....]: gauge (or no gauge)
kMG[...]: ?,?,?,?,?

???? Now that I know what the problem is how do I fix it? thanks for the
help from everyone that replied to this...


Britt Tabor
I.T. Infrastructure Engineer



-----Original Message-----
From: Takumi Yamane [mailto:[EMAIL PROTECTED] 
Sent: Friday, August 06, 2004 4:54 PM
To: [EMAIL PROTECTED]
Subject: [mrtg] Re: Logfile problem

On Fri, 6 Aug 2004 16:16:15 -0400, "Britt Tabor" wrote 
in <[EMAIL PROTECTED]>:
>
> Here is the outtake from my .cfg file for one of the interfaces...

Is there anything like this:
  Options[_]: gauge
or similar in your config file?

Like I said, I think you have enabled 'gauge' option, and its the 
plausible cause.

-- 
Takumi Yamane <[EMAIL PROTECTED]>

--
Unsubscribe mailto:[EMAIL PROTECTED]
Archive     http://www.ee.ethz.ch/~slist/mrtg
FAQ         http://faq.mrtg.org    Homepage     http://www.mrtg.org
WebAdmin    http://www.ee.ethz.ch/~slist/lsg2.cgi


--
Unsubscribe mailto:[EMAIL PROTECTED]
Archive     http://www.ee.ethz.ch/~slist/mrtg
FAQ         http://faq.mrtg.org    Homepage     http://www.mrtg.org
WebAdmin    http://www.ee.ethz.ch/~slist/lsg2.cgi

Reply via email to