You either need to use 32bit counters, or when you probed it, it only came back 100, instead of 1000
On Thu, May 6, 2010 at 3:19 PM, <[email protected]> wrote: > Hi Everyone, > > I am probing a cisco 3500 and a number of windows machines. When the > traffic goes over 150MB via the 3500 to one of the machines I start getting > incorrect data from the 3500. I thought the problem was the 3500 and was > about to replace it but then the problem occured in another 3500 as well > as one of the machines. I decreased the probe time (cron job) from 5 > minutes > to 3 minutes and that fixed the problem until the traffic went over 250MB. > I am also logging the mrtg so I can send logs if need be. > Any ideas??? > > > - > sysadm cronomagic.com > e-mail [email protected] > > POWERED BY LINUX > > _______________________________________________ > mrtg mailing list > [email protected] > https://lists.oetiker.ch/cgi-bin/listinfo/mrtg > -- Anson Rinesmith Network Operations Big River Telephone Co. 24 S. Minnesota Cape Girardeau, MO 63702-1608 (573) 651-3373 Attendant (573) 388-3701 Direct (573) 651-3605 Fax (573) 382-0555 Cell Real People, Real Service, Real Simple.
_______________________________________________ mrtg mailing list [email protected] https://lists.oetiker.ch/cgi-bin/listinfo/mrtg