Dmitry K. wrote:

On 10 Jan 2004 13:20 Steve Underwood wrote:
Do you knwo of an external reset controller that consumes just a few
nano amps, and won't destroy the low power qualities of the 149? :-\


Nano??
Enough old MAX811*:  5 - 6 micro amps at a distance from reset level
(this is tested).

Regards.

5-6uA would really screw up my 149 products currently consuming about 1uA. I think the battery life would suffer a little :-)

You can get reset devices below 1uA, but that still nearly doubles the current consumption.

Regards,
Steve