Definitely, absolutely degassing.  Sorry to say, but that tube is a "goner".  
You can tell by the fact that some cathodes show a larger area of discharge 
towards the end of the one-second cycle.  Not enough neon/argon to effect 
complete discharge.  Also, the cathodes should glow more purple when gas is low.

>
>IN-18 is losing digits, is this due to age, degassing, cathode
>posioning?
>
>http://www.youtube.com/watch?v=E3ZergZdHbs
>
>Any help would be appreciated.
>
>Thanks,
>
>John
>
>-- 