> Its not wrong - its just how you read it - if you click on the
> components (C15 & C16), you'll see that it has X2 or X3 at the end of
> the description - this means use two or three in series - this is
> simply a limitation of the DC ratings of the electrolytic capacitors
> that are currently in the component database - the schematic is fine -
> you can replace the two series caps with a single higher rated one if
> you so wish. You can ask them to add some 500VDC caps if you want!

Thanks for that clarification, I did not spot that as they were drawn
as a single capacitor in the schematic. They should have added a note
or something as just putting three electrlytics in series without
voltage dividing resistors is not that good.

I'll check it more now that I know of that aspect!

-- 