> Its not wrong - its just how you read it - if you click on the > components (C15 & C16), you'll see that it has X2 or X3 at the end of > the description - this means use two or three in series - this is > simply a limitation of the DC ratings of the electrolytic capacitors > that are currently in the component database - the schematic is fine - > you can replace the two series caps with a single higher rated one if > you so wish. You can ask them to add some 500VDC caps if you want!
Thanks for that clarification, I did not spot that as they were drawn as a single capacitor in the schematic. They should have added a note or something as just putting three electrlytics in series without voltage dividing resistors is not that good. I'll check it more now that I know of that aspect! -- You received this message because you are subscribed to the Google Groups "neonixie-l" group. To post to this group, send an email to [email protected]. To unsubscribe from this group, send email to [email protected]. For more options, visit this group at http://groups.google.com/group/neonixie-l?hl=en-GB.