Hi everyone,

I need help with my newly built clock. The thing is, after I turn it on and 
the clock runs for like 5-10mins, some of the digits on tubes become 
partially lit like on the picture. Now, I noticed the power supply gets 
very hot after running for 5-10mins and I measured the voltage on +HV 
(+185V) pin of the power supply while the clock is running. It seems like 
the voltage keeps dropping as the supply gets hotter (last time I measure 
it, it went down to 148V and these artifacts became showing on the tubes. 
The digit usually lights up normally at first, then after the cathode 
poisoning routing it becomes partially lit like on the first picture, then 
after the second cathode poisoning routine, it gets partially lit like on 
the second picture and so on, it shows on all of the tubes at some times. 
I'm using 27k anode resistors on IN-14 tubes and I guess the power supply 
is of the design from the picture I attached.

Thanks in advance!

<https://threeneurons.files.wordpress.com/2011/08/mc34063_m1bad_b.gif>

Power supply design (I suppose)


<https://lh3.googleusercontent.com/-tWX7o41vLGo/VgABPh-hTCI/AAAAAAAAAEg/rmwkNiodFxw/s1600/IMG_20150920_030556%255B1%255D.jpg>


<https://lh3.googleusercontent.com/-4_1qUwrCX7k/VgABgjPr3OI/AAAAAAAAAEo/nE9UobiBRoY/s1600/IMG_20150920_030543%255B1%255D.jpg>




-- 
You received this message because you are subscribed to the Google Groups 
"neonixie-l" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To post to this group, send an email to [email protected].
To view this discussion on the web, visit 
https://groups.google.com/d/msgid/neonixie-l/7e4a8d74-0446-4bf1-829e-787929329f51%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

Reply via email to