@gregebert I'd be interested in seeing your best-known methods for power 
supplies.


On Monday, September 21, 2015 at 7:11:27 AM UTC-6, Luka C wrote:
>
> Hi everyone,
>
> I need help with my newly built clock. The thing is, after I turn it on 
> and the clock runs for like 5-10mins, some of the digits on tubes become 
> partially lit like on the picture. Now, I noticed the power supply gets 
> very hot after running for 5-10mins and I measured the voltage on +HV 
> (+185V) pin of the power supply while the clock is running. It seems like 
> the voltage keeps dropping as the supply gets hotter (last time I measure 
> it, it went down to 148V and these artifacts became showing on the tubes. 
> The digit usually lights up normally at first, then after the cathode 
> poisoning routing it becomes partially lit like on the first picture, then 
> after the second cathode poisoning routine, it gets partially lit like on 
> the second picture and so on, it shows on all of the tubes at some times. 
> I'm using 27k anode resistors on IN-14 tubes and I guess the power supply 
> is of the design from the picture I attached.
>
> Thanks in advance!
>
> <https://threeneurons.files.wordpress.com/2011/08/mc34063_m1bad_b.gif>
>
> Power supply design (I suppose)
>
>
>
> <https://lh3.googleusercontent.com/-tWX7o41vLGo/VgABPh-hTCI/AAAAAAAAAEg/rmwkNiodFxw/s1600/IMG_20150920_030556%255B1%255D.jpg>
>
>
>
> <https://lh3.googleusercontent.com/-4_1qUwrCX7k/VgABgjPr3OI/AAAAAAAAAEo/nE9UobiBRoY/s1600/IMG_20150920_030543%255B1%255D.jpg>
>
>
>
>
>

-- 
You received this message because you are subscribed to the Google Groups 
"neonixie-l" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To post to this group, send an email to [email protected].
To view this discussion on the web, visit 
https://groups.google.com/d/msgid/neonixie-l/bafc7461-7f99-4bc9-a7b6-c15dadee3b0b%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

Reply via email to