Congratulations, you've avoided a lot of problems with direct-drive and the MPSA42 drivers. I have to admire your bravery with the point-to-point wiring. Very impressive, especially for a first clock.
Nothing wrong with the relay to control the HVDC supply; just make sure you have a diode across the coil to clamp the inductive spike when the coil is de-energized. It's far better to shut the HV down when the tubes are off, rather than letting it run with no load. -- You received this message because you are subscribed to the Google Groups "neonixie-l" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To post to this group, send an email to [email protected]. To view this discussion on the web, visit https://groups.google.com/d/msgid/neonixie-l/768642f3-4ce3-476b-877f-24d3a08e04c6%40googlegroups.com. For more options, visit https://groups.google.com/d/optout.