On Mon, Jul 12, 2004 at 09:57:30AM -0700, Steve Sanders wrote:
> Several times now I have tried to scan subnets on my company's network, but on a 
> number of these occasions the client appears to lose its connection to the server.  
> When this happens, the scan appears to hang for an extremely long time.  After 15-30 
> minutes of no movement I shut the complete scan down and as soon as I do, I see a 
> message saying the client is disconnected. 

If you get such a message when you actually kill the client, it means
that the connection was not lost at all. You may want to do a "ps auxw"
on the nessusd side to see which processes are still there - maybe you
have hydra running (takes a _long_ time) or maybe one of the scanned
box has a personal firewall on it, so your port scanner is not done yet.


                                -- Renaud