2009/9/1 <[email protected]>: > 1. Is it really required for snmpd to go for a reconfig for SIGHUP signal ?
That's the purpose of the HUP signal - to request the agent to reload the configuration. > 2. What if the SIGHUP signal handler is modified as to do nothing ? Then it won't reload the config on demand. If that's not a problem for you, then go ahead. > 3. Is there any patch for this to solve the issue ( error on > subcontainer '' insert (-1)) As I said, I believe this problem has been fixed in a later release. I can't recall exactly when this problem was fixed or what the patch was. All I can suggest is that you try experimenting with these later releases (on a test system), and try to identify first when this problem disappears, and then the code responsible. You should then be able to back-port this patch to your code base. But I'm afraid we don't have the time/resources to chase old fixes for obsolete releases. Dave ------------------------------------------------------------------------------ Let Crystal Reports handle the reporting - Free Crystal Reports 2008 30-Day trial. Simplify your report design, integration and deployment - and focus on what you do best, core application coding. Discover what's new with Crystal Reports now. http://p.sf.net/sfu/bobj-july _______________________________________________ Net-snmp-coders mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/net-snmp-coders