From: Eric Nelson <e...@nelint.com> Date: Fri, 23 Sep 2016 11:35:17 -0700
> From the i.MX6DQ reference manual, bit 7 of ENET_RACC says this: > > "RX FIFO Shift-16 > > When this field is set, the actual frame data starts at bit 16 of the first > word read from the RX FIFO aligning the Ethernet payload on a > 32-bit boundary." > > Same for the i.MX6UL. > > I'm not sure what it will take to use this, but it seems to be exactly > what we're looking for. +1