Hi Edward, indeed, no models have been selected for any of the residues. That might be, logically, the problem. This is the message I read after each of the nine attempted models:
"RelaxWarning: No spins are selected therefore the optimisation or calculation cannot proceed." Suggestions? Stefano > On 12 Jul 2019, at 15:57, Edward d'Auvergne <[email protected]> wrote: > > On Fri, 12 Jul 2019 at 15:16, Stefano Luciano Ciurli > <[email protected]> wrote: >> >> Hi Edward, >> I hope I am sending the message to the correct address now. >> >> I think I have solved the issue that was causing the mentioned problem with >> the apparently incomplete set up by doing what you indicated. >> >> Now the calculation has gone for about 5 min with the following result: >> >> ================================================================== >> = Completion of the d'Auvergne protocol model-free auto-analysis = >> ================================================================== >> >> Elapsed time: 5 minutes and 54.350 seconds >> >> Exception raised in thread. >> >> Traceback (most recent call last): >> File "gui/analyses/execute.pyc", line 87, in run >> File "gui/analyses/auto_model_free.pyc", line 834, in run_analysis >> File "auto_analyses/dauvergne_protocol.pyc", line 249, in __init__ >> File "auto_analyses/dauvergne_protocol.pyc", line 610, in execute >> File "auto_analyses/dauvergne_protocol.pyc", line 855, in model_selection >> File "prompt/uf_objects.pyc", line 161, in __call__ >> File "pipe_control/model_selection.pyc", line 260, in select >> File "pipe_control/pipes.pyc", line 68, in bundle >> File "lib/checks.pyc", line 81, in __call__ >> RelaxNoPipeError: RelaxError: The data pipe 'aic - mf (Sun Jul 7 18:21:56 >> 2019)' has not been created yet. >> >> What should I make of it? > > Cheers! The error message has been seen before: > > > http://www.nmr-relax.com/mail.gna.org/public/relax-users/2012-11/msg00005.html > > http://www.nmr-relax.com/mail.gna.org/public/relax-users/2008-11/msg00034.html > > However I've never had a bug report with enough details to reproduce > the problem to be able to catch it in the test suite. My guess is > that if you carefully look at the log messages (hopefully you ran it > with the log output to file), you'll see a series of RelaxWarning > messages earlier which explain the problem in detail. I would also > guess that no models have been select for one or more spin systems. > > Regards, > > Edward _______________________________________________ nmr-relax-announce mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/nmr-relax-announce