Hello NONMEM Users,
 
Subjects received IV infusion (study 2), IV injection or SQ injection (study1). 
 In addition, I had to inject a dummy (amt=1) dose into the 3rd compartment, 
which describes the target.  2 studies were integrated.  The time-concentration 
plots looked good for one study (IV injection or SC infusion) and 
meaningless/really bad for the other one (IV infusion;  population-predicted 
values were a few-fold different from the observed ones).  The data look 
correct.  The rate, dose, and times look fine (rate=amt/infusion_duration; the 
first measure is taken after the end off infusion).  When I set Rate=0 for the 
second study, the outcome looks perfect for both studies; the objective 
function decreased a lot.  Because I do not feel comfortable using Rate=0, I 
tried to change the order of the dummy and real doses, set time of the real 
dose to 1 second, etc.  Nothing works.  It looks like a NONMEM bug.  
 
Thank you,
Pavel

Reply via email to