That device is not currently supported (we have never seen it before). It looks like a HID device, so it should be possible to write a subdriver for it, see docs/hid-subdrivers.txt.
However, the data returned by the device looks strange; all the values are "0". I am not sure if this will work out. -- Peter Lau Kim Ping wrote: > > *********************** > Your mail has been scanned by InterScan MSS. > *********************** > > > Has anyone managed to get this UPS to work? I am using the laster > development nuts. My /proc/bus/usb/devices content: > > ==== cut ==== > T: Bus=01 Lev=01 Prnt=01 Port=01 Cnt=01 Dev#= 2 Spd=1.5 MxCh= 0 > D: Ver= 1.00 Cls=00(>ifc ) Sub=00 Prot=00 MxPS= 8 #Cfgs= 1 > P: Vendor=ffff ProdID=0000 Rev= 1.00 > S: Manufacturer=UIS Ablerex > S: Product=Ablerex USB Interface 049e > C:* #Ifs= 1 Cfg#= 1 Atr=80 MxPwr=100mA > I: If#= 0 Alt= 0 #EPs= 0 Cls=03(HID ) Sub=00 Prot=00 Driver=(none) > ==== cut ==== > > "newhidups -DD -u root -x generic -x vendorid=ffff auto" gave me this: > > debug level is '2' > Checking device (FFFF/0000) (001/002) > - VendorID: ffff > - ProductID: 0000 > - Manufacturer: UIS Ablerex > - Product: Ablerex USB Interface 049e > - Serial Number: unknown > - Bus: 001 > Trying to match device > Device matches > HID descriptor retrieved (Reportlen = 632) > Report descriptor retrieved (Reportlen = 632) > Found HID device > Report Descriptor size = 632 > Detected a UPS: UIS Ablerex/Ablerex USB Interface 049e > Using subdriver: GENERIC HID 0.1 > Network UPS Tools: 0.28 USB communication driver 0.28 - core 0.30 > (2.1.0) > > Path: 00860004.Flow.FlowID, Type: Feature, Value: 0.000000 > Path: 00860004.Flow.ConfigVoltage, Type: Feature, Value: 0.000000 > Path: 00860004.Flow.ConfigFrequency, Type: Feature, Value: 0.000000 > Path: 00860004.Flow.LowVoltageTransfer, Type: Feature, Value: 0.000000 > Path: 00860004.Flow.HighVoltageTransfer, Type: Feature, Value: 0.000000 > Path: 00860004.Flow.iManufacturer, Type: Feature, Value: 0.000000 > Path: 00860004.Flow.iProduct, Type: Feature, Value: 0.000000 > Path: 00860004.Flow.iSerialNumber, Type: Feature, Value: 0.000000 > Path: 00860004.Flow.FlowID, Type: Feature, Value: 0.000000 > Path: 00860004.Flow.ConfigVoltage, Type: Feature, Value: 0.000000 > Path: 00860004.Flow.ConfigFrequency, Type: Feature, Value: 0.000000 > Path: 00860004.Flow.ConfigApparentPower, Type: Feature, Value: 0.000000 > Path: 00860004.Flow.ConfigActivePower, Type: Feature, Value: 0.000000 > Path: 00860004.Flow.DelayBeforeStartup, Type: Feature, Value: 0.000000 > Path: 00860004.Flow.DelayBeforeShutdown, Type: Feature, Value: 0.000000 > Path: 00860004.BatterySystem.BatterySystemID, Type: Feature, Value: > 0.000000 > Path: 00860004.BatterySystem.PresentStatus.Used, Type: Feature, Value: > 0.000000 > Path: 00860004.BatterySystem.PresentStatus.Good, Type: Feature, Value: > 0.000000 > Path: 00860004.BatterySystem.Voltage, Type: Feature, Value: 0.000000 > Path: 00860004.BatterySystem.Temperature, Type: Feature, Value: 0.000000 > Path: 00860004.BatterySystem.Test, Type: Input, Value: 0.000000 > Path: 00860004.BatterySystem.Test, Type: Feature, Value: 0.000000 > Can't find object 00860004.PowerConverter.PowerConverterID > Path: 00860004.PowerConverter.PowerConverterID, Type: Input > Can't find object 00860004.PowerConverter.Input.InputID > Path: 00860004.PowerConverter.Input.InputID, Type: Input > Can't find object 00860004.PowerConverter.Input.FlowID > Path: 00860004.PowerConverter.Input.FlowID, Type: Input > Can't find object 00860004.PowerConverter.Input.PresentStatus.Good > Path: 00860004.PowerConverter.Input.PresentStatus.Good, Type: Input > Can't find object 00860004.PowerConverter.Input.Voltage > Path: 00860004.PowerConverter.Input.Voltage, Type: Input > Can't find object 00860004.PowerConverter.Input.Frequency > Path: 00860004.PowerConverter.Input.Frequency, Type: Input > Can't find object 00860004.PowerConverter.Output.OutputID > Path: 00860004.PowerConverter.Output.OutputID, Type: Input > Can't find object 00860004.PowerConverter.Output.FlowID > Path: 00860004.PowerConverter.Output.FlowID, Type: Input > Can't find object 00860004.PowerConverter.Output.Voltage > Path: 00860004.PowerConverter.Output.Voltage, Type: Input > Can't find object 00860004.PowerConverter.Output.Frequency > Path: 00860004.PowerConverter.Output.Frequency, Type: Input > Can't find object 00860004.PowerConverter.Output.PercentLoad > Path: 00860004.PowerConverter.Output.PercentLoad, Type: Input > Can't find object 00860004.PowerConverter.Output.PresentStatus.Overload > Path: 00860004.PowerConverter.Output.PresentStatus.Overload, Type: Input > Can't find object 00860004.PowerConverter.Output.PresentStatus.Boost > Path: 00860004.PowerConverter.Output.PresentStatus.Boost, Type: Input > Can't find object 00860004.PowerConverter.Output.PresentStatus.Buck > Path: 00860004.PowerConverter.Output.PresentStatus.Buck, Type: Input > Path: 00860004.PowerConverter.Output.PresentStatus.00840039, Type: > Feature, Value: 0.000000 > upsdrv_updateinfo... > dstate_init: sock /var/state/ups/newhidups-auto open on fd 5 > upsdrv_updateinfo... > Waiting for notifications... > > Signal 2: exiting > Closing device > > > _______________________________________________ > Nut-upsuser mailing list > [email protected] > http://lists.alioth.debian.org/mailman/listinfo/nut-upsuser > _______________________________________________ Nut-upsuser mailing list [email protected] http://lists.alioth.debian.org/mailman/listinfo/nut-upsuser