Hi Viswa, Not really. The onboarding process (SDC + demo.sh in the robot VM) populates ONAP components with metadata about the VNF that you want to run. Those steps are required for the closed loop to work correctly.
Also, regarding the vLB, we are testing it for ONAP 1.1.0 but we still have some issue with the DNS scaling scenario. So, for the scaling use case you may want to see what we did for ONAP 1.0.0. Thanks, Marco From: <[email protected]> on behalf of "Kumar Skand Priya, Viswanath V via onap-discuss" <[email protected]> Reply-To: "Kumar Skand Priya, Viswanath V" <[email protected]> Date: Tuesday, August 22, 2017 at 11:03 AM To: "DRAGOSH, PAMELA L (PAM)" <[email protected]> Cc: "[email protected]" <[email protected]> Subject: Re: [onap-discuss] [E] Re: Closed Loop Question Thanks Pam. I shall try vDNS as suggested. BTW Is there a way we can skip the SDC on-boarding steps and directly start with deployment + scaling ?? BR, Viswa [http://ss7.vzw.com/is/image/VerizonWireless/vz-sig-verizon?$defaultscale$]<https://urldefense.proofpoint.com/v2/url?u=http-3A__www.verizon.com&d=DwMFaQ&c=LFYZ-o9_HUMeMTSQicvjIg&r=KgFIQiUJzSC0gUhJaQxg8eC3w16GC3sKgWIcs4iIee0&m=TYE6HdAJosx0j0ckbJqHiItzrnuMkRAUm07SzHz8D2I&s=LpqXsu4ntmHCIYVij_-YymkSfIcd5cFARh8byEN2GhE&e=> Viswanath Kumar Skand Priya Architect SDN, Cloud Services & Orchestration On Tue, Aug 22, 2017 at 8:26 PM, DRAGOSH, PAMELA L (PAM) <[email protected]<mailto:[email protected]>> wrote: Viswa, The vDNS (also call vLB) use case does VNF scaling. It is very basic. ☺ Regards, Pam From: <[email protected]<mailto:[email protected]>> on behalf of "Kumar Skand Priya, Viswanath V via onap-discuss" <[email protected]<mailto:[email protected]>> Reply-To: "Kumar Skand Priya, Viswanath V" <[email protected]<mailto:[email protected]>> Date: Tuesday, August 22, 2017 at 10:45 AM To: Josef Reisinger <[email protected]<mailto:[email protected]>> Cc: "[email protected]<mailto:[email protected]>" <[email protected]<mailto:[email protected]>> Subject: Re: [onap-discuss] [E] Re: Closed Loop Question Hi Josef, Thanks for the note. Does this mean that, currently we cannot use ONAP to perform scaling / healing of VNFs ? Could you let me know if there are any other demo available today, which takes use through closed loop? Can the CLAMP project be leveraged to demonstrate closed loop? PS : Bharath works with me on ONAP exploration! BR, Viswa [http://ss7.vzw.com/is/image/VerizonWireless/vz-sig-verizon?$defaultscale$]<https://urldefense.proofpoint.com/v2/url?u=http-3A__www.verizon.com&d=DwMFaQ&c=LFYZ-o9_HUMeMTSQicvjIg&r=jwTiArcEj6aUX0HjV0M3dT12gUtk7rC07xpgpVZkS_4&m=qWoY_xw3Vs-N_sofCThrKlfCYjsUSL8K4gQOA9zK_Ls&s=_r9QB-B4NklThucc4VpdnK8UStN6nHFgoPD6JgKAioI&e=> Viswanath Kumar Skand Priya Architect SDN, Cloud Services & Orchestration On Tue, Aug 22, 2017 at 2:15 PM, Josef Reisinger <[email protected]<mailto:[email protected]>> wrote: I run the basic vFW demo right now and this does not include scaling of the VMs. It includes changing the package rate of the package generator (keeping it constant). To change the packet rate, there is a REST API. Not sure I got your Q'#2 right, the closes "loop" consists of the vFW as the source of measurements, DCAE to process the measurements and CDAP to run an APP die determine whether the packet rate it too high, Policy & APPC to close the loop (roughly, see more details here: https://wiki.onap.org/display/DW/Tutorial%3A+Verifying+and+Observing+a+deployed+Service+Instance<https://urldefense.proofpoint.com/v2/url?u=https-3A__wiki.onap.org_display_DW_Tutorial-253A-2BVerifying-2Band-2BObserving-2Ba-2Bdeployed-2BService-2BInstance&d=DwMFAw&c=udBTRvFvXC5Dhqg7UHpJlPps3mZ3LRxpb6__0PomBTQ&r=9F3pNUkzjE-2v1eTClkRVTaKybM-QdOEEflZQ1UA1C3bK3Y3fLmJGlCViaBBmZar&m=vEBN4n4tgbnL2721l_9VHKSP7C0UejdO-PkR8ypFO4c&s=XiryG8oNDAXcn3WUE1emsISKDJ6_O5XXWcG2CER92bY&e=>) The vFW VMs have different # of network interfaces, three for the sink & pgn nodes, 4 for the firewall node. Running vFW demo on another openstack instance can become a bit tricky maybe, I am not sure the the entire comms runs via the "public" network. If you run into issues, you should keep that as a probable cause of issues in mind. Mit freundlichen Grüßen / Kind regards Josef Reisinger From: bharath thiruveedula <[email protected]<mailto:[email protected]>> To: Josef Reisinger <[email protected]<mailto:[email protected]>> Date: 22.08.2017 10:23 Subject: Closed Loop Question ________________________________ Hi Josef, I think you played well with DCAE part :) I am currently looking to make closed loop work with vFW. I have few questions on this: 1)Can we scale up/down the VNFs in vFW demo using some rest apis. 2)Can we scale using just policy VM and MSO VM? 3) What are the minimum network interfaces we need to attach vFW VMs as I am launching vFW in different openstack and ONAP is running in different openstack? Any help is greatly appreciated Josef! Best Regards Bharath T _______________________________________________ onap-discuss mailing list [email protected]<mailto:[email protected]> https://urldefense.proofpoint.com/v2/url?u=https-3A__lists.onap.org_mailman_listinfo_onap-2Ddiscuss&d=DwICAg&c=udBTRvFvXC5Dhqg7UHpJlPps3mZ3LRxpb6__0PomBTQ&r=9F3pNUkzjE-2v1eTClkRVTaKybM-QdOEEflZQ1UA1C3bK3Y3fLmJGlCViaBBmZar&m=vEBN4n4tgbnL2721l_9VHKSP7C0UejdO-PkR8ypFO4c&s=ZZ06_-do3YUwE1DVwDknqx8OstUn8nxUaCbF1NdMGdc&e=
_______________________________________________ onap-discuss mailing list [email protected] https://lists.onap.org/mailman/listinfo/onap-discuss