Looks like it's implementation of the "Centralized Representation and Consistent Identification of Cloud Regions" use case, which VID will only support in Dublin.
Seshu, may you tweak this flow to accept cloudRegionId alone? In Dublin we'll be able to send cloudOwner as well. Thanks, Ofir From: Kuzmicki, Krzysztof (Nokia - PL/Wroclaw) [mailto:[email protected]] Sent: Tuesday, October 23, 2018 4:04 PM To: [email protected]; [email protected]; Muszkieta, Lukasz (Nokia - PL/Wroclaw) <[email protected]>; Sonsino, Ofir <[email protected]>; FREEMAN, BRIAN D <[email protected]>; [email protected] Cc: [email protected]; Przybysz, Marcin (Nokia - PL/Wroclaw) <[email protected]>; Kukulski, Marek (Nokia - PL/Wroclaw) <[email protected]>; Pondel, Marek (Nokia - PL/Wroclaw) <[email protected]>; Nowak, Damian (Nokia - PL/Wroclaw) <[email protected]>; Kuzmicki, Krzysztof (Nokia - PL/Wroclaw) <[email protected]> Subject: Odp.: Suspected SPAM - [onap-discuss] [Integration][SO][VID] problem with instantiation vCPE service -> PnP PNF + @[email protected] br, Krzysztof ________________________________ Od: [email protected]<mailto:[email protected]> <[email protected]<mailto:[email protected]>> w imieniu użytkownika Krzysztof Kuźmicki <[email protected]<mailto:[email protected]>> Wysłane: wtorek, 23 października 2018 14:38 Do: [email protected]<mailto:[email protected]>; Muszkieta, Lukasz (Nokia - PL/Wroclaw) DW: [email protected]<mailto:[email protected]>; [email protected]<mailto:[email protected]>; FREEMAN, BRIAN D; [email protected]<mailto:[email protected]>; Przybysz, Marcin (Nokia - PL/Wroclaw); Kukulski, Marek (Nokia - PL/Wroclaw); Pondel, Marek (Nokia - PL/Wroclaw) Temat: Suspected SPAM - [onap-discuss] [Integration][SO][VID] problem with instantiation vCPE service -> PnP PNF Hi During integration tests for PnP PNF we noticed interface inconstancy between VID and SO For PnP PNF work-flow we are using modified fork of /mso/async/services/CreateGenericALaCarteServiceInstance bpmn work-flow -->> /mso/async/services/CreateVcpeResCustService_simplified For this issue has been reported bug: https://jira.onap.org/browse/SO-1156<https://urldefense.proofpoint.com/v2/url?u=https-3A__jira.onap.org_browse_SO-2D1156&d=DwMFBA&c=LFYZ-o9_HUMeMTSQicvjIg&r=YKrlt1M487Gbcxf6GKUYkdaaJq4RCPChFI2AKdT_bP8&m=ERPxuZNQN64fF79SW22h7o4_VP36OxB75bL4LCBDcZE&s=JwduohI6-MeUdUGIgfjpoihYVpdDAq9ze5DckfujA1w&e=> In short words. In case of any vCPE service instantiation in SO, in bpmn flow in CreateVcpeResCustService - preProcessRequest is present check if VID has sent, in parameter lcpCloudRegionId both cloudOwner and cloudRegionId separated using "_" . Unfortuantelly VID sends only cloudRegionId. As @Muszkieta, Lukasz (Nokia - PL/Wroclaw)<mailto:[email protected]> checked for other services such check doesn't exists. Did you tried during integration test activities instantiate any vCPE service and noticed such problem? br, Krzysztof -=-=-=-=-=-=-=-=-=-=-=- Links: You receive all messages sent to this group. View/Reply Online (#13229): https://lists.onap.org/g/onap-discuss/message/13229 Mute This Topic: https://lists.onap.org/mt/27569007/21656 Group Owner: [email protected] Unsubscribe: https://lists.onap.org/g/onap-discuss/unsub [[email protected]] -=-=-=-=-=-=-=-=-=-=-=-