Hi Michael In the same env we are also getting the info, it seems the issue is due to the CSAR generated is of bad format. Request your help in identifying what could have gone wrong. Looking forward :)
it seems there is issue in csar: 2018-11-13T18:05:51.379Z|b8bd8edb-62da-404b-b7b9-80e9f62e1afa| o.onap.sdc.tosca.parser.impl.SdcToscaParserFactory - ToscaTemplate - verifyTemplate - 1 Parsing Critical occurred... 2018-11-13T18:05:51.379Z|b8bd8edb-62da-404b-b7b9-80e9f62e1afa| o.onap.sdc.tosca.parser.impl.SdcToscaParserFactory - JTosca Exception [JE136]: InvalidTypeError: "tosca.services.Root" is not a valid type. C SAR name - /app/null/ASDC/1/service-Siteservice-csar.csar 2018-11-13T18:05:51.379Z|b8bd8edb-62da-404b-b7b9-80e9f62e1afa| org.onap.so.asdc.installer.ToscaResourceStructure - ASDC_GENERAL_EXCEPTION_ARG org.onap.sdc.tosca.parser.exceptions.SdcToscaParserException: Error: CSAR file bad format. Check the log for details. at org.onap.sdc.tosca.parser.impl.SdcToscaParserFactory.throwSdcToscaParserException(SdcToscaParserFactory.java:196) at org.onap.sdc.tosca.parser.impl.SdcToscaParserFactory.init(SdcToscaParserFactory.java:89) at org.onap.sdc.tosca.parser.impl.SdcToscaParserFactory.getSdcCsarHelper(SdcToscaParserFactory.java:60) at org.onap.so.asdc.installer.ToscaResourceStructure.updateResourceStructure(ToscaResourceStructure.java:137) at org.onap.so.asdc.client.ASDCController.processCsarServiceArtifacts(ASDCController.java:770) at org.onap.so.asdc.client.ASDCController.processResourceNotification(ASDCController.java:688) at org.onap.so.asdc.client.ASDCController.treatNotification(ASDCController.java:576) at org.onap.so.asdc.client.ASDCNotificationCallBack.activateCallback(ASDCNotificationCallBack.java:55) at org.onap.sdc.impl.NotificationConsumer.run(NotificationConsumer.java:71) at java.util.concurrent.Executors$RunnableAdapter.call(Executors.java:511) at java.util.concurrent.FutureTask.runAndReset(FutureTask.java:308) at java.util.concurrent.ScheduledThreadPoolExecutor$ScheduledFutureTask.access$301(ScheduledThreadPoolExecutor.java:180) Thanks and Regards, M Seshu Kumar Senior System Architect uTraffic, Software BU, Huawei Technologies India Pvt. Ltd. Survey No. 37, Next to EPIP Area, Kundalahalli, Whitefield Bengaluru-560066, Karnataka. Tel: + 91-80-49160700 , Mob: 9845355488 ___________________________________________________________________________________________________ This e-mail and its attachments contain confidential information from HUAWEI, which is intended only for the person or entity whose address is listed above. Any use of the information contained herein in any way (including, but not limited to, total or partial disclosure, reproduction, or dissemination) by persons other than the intended recipient(s) is prohibited. If you receive this e-mail in error, please notify the sender by phone or email immediately and delete it! ------------------------------------------------------------------------------------------------------------------------------------------------------------------- ________________________________ From: onap-discuss@lists.onap.org [onap-discuss@lists.onap.org] on behalf of Yan Yang [yangya...@chinamobile.com] Sent: Thursday, November 15, 2018 8:55 PM To: onap-discuss@lists.onap.org; michael.la...@intl.att.com; krzysztof.kuzmi...@nokia.com Cc: Yunxia Chen; 'Pondel, Marek (Nokia - PL/Wroclaw)'; 'Przybysz, Marcin (Nokia - PL/Wroclaw)' Subject: 答复: [onap-discuss] [SDC][Integration] Error during "Certify" operation Hi Michal, We also encounter the following issue in our testing and tried the two options you mentioned ,but it didn’t work. Can you give more tips how to solve it. Error Error code: SVC4661 Status code: 400 CSAR packaging failed. TOSCA schema files for SDC-Version: 1.3.3 and Conformance-Level 9.0 were not found Best Regards, Yan 发件人: onap-discuss@lists.onap.org [mailto:onap-discuss@lists.onap.org] 代表 Michael Lando 发送时间: 2018年11月6日 8:04 收件人: onap-discuss@lists.onap.org; krzysztof.kuzmi...@nokia.com 抄送: helen.c...@huawei.com; Pondel, Marek (Nokia - PL/Wroclaw); Przybysz, Marcin (Nokia - PL/Wroclaw) 主题: Re: [onap-discuss] [SDC][Integration] Error during "Certify" operation Hi, I believe the error you are getting is because the job that needs to update our db did not run as it has already run once (Cassandra init) You can delete the k8s job and restart sdc and it should be fine. From the portal perspective portal moved to use https and as sdc did not the browser has an issue with that. You have two options: 1. Use the portal in http mode port 30215 . 2. Allow the browser to work in this way. BR, [Michael Lando] AT&T Network Application Development ・ NetCom Tel Aviv | Tampa | Atlanta | New Jersey |Chicago ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Office: +972 (3) 5451487 Mobile: +972 (54) 7833603 e-mail: michael.la...@intl.att.com<mailto:michael.la...@intl.att.com> From: onap-discuss@lists.onap.org<mailto:onap-discuss@lists.onap.org> <onap-discuss@lists.onap.org<mailto:onap-discuss@lists.onap.org>> On Behalf Of Krzysztof Kuzmicki Sent: Monday, November 05, 2018 16:53 To: onap-discuss@lists.onap.org<mailto:onap-discuss@lists.onap.org> Cc: helen.c...@huawei.com<mailto:helen.c...@huawei.com>; Pondel, Marek (Nokia - PL/Wroclaw) <marek.pon...@nokia.com<mailto:marek.pon...@nokia.com>>; Przybysz, Marcin (Nokia - PL/Wroclaw) <marcin.przyb...@nokia.com<mailto:marcin.przyb...@nokia.com>> Subject: [onap-discuss] [SDC][Integration] Error during "Certify" operation Hi Today we were able to install locally whole Casablanca staging version including Brian's work around regarding failing message router :). However during PNF creation in SDC as Carlos Santana user during certify operation following error has appear: Error Error code: SVC4661 Status code: 400 CSAR packaging failed. TOSCA schema files for SDC-Version: 1.3.3 and Conformance-Level 9.0 were not found Has anybody seen this issue. At this lab whole robot init (./demo-k8s.sh onap init) was successful Health check has failed only at: Basic APPC Health Check | FAIL | 401 != 200< Also we noticed that SDC is not opening in portal widget ther is need to copy link from web browser console and use it directly (for example http://sdc.api.fe.simpledemo.onap.org:30206/sdc1/portal?cc=1541428669289<https://urldefense.proofpoint.com/v2/url?u=http-3A__sdc.api.fe.simpledemo.onap.org-3A30206_sdc1_portal-3Fcc-3D1541428669289&d=DwMFBA&c=LFYZ-o9_HUMeMTSQicvjIg&r=h6d8s-s1RrgnbmvrBfu9-5GJbGW2pVMGpcRjivm8njo&m=9dXXSk6-CL2hZSDkulVeHnoXUDmrZ2Nhj7bp1rEwj0o&s=THdo6xEeVOeFzYQBdBNQMmYVgZJF77gn3FiupvazeRo&e=>) Has anybody reported this issue ? br, Krzysztof -=-=-=-=-=-=-=-=-=-=-=- Links: You receive all messages sent to this group. View/Reply Online (#13762): https://lists.onap.org/g/onap-discuss/message/13762 Mute This Topic: https://lists.onap.org/mt/28145719/21656 Group Owner: onap-discuss+ow...@lists.onap.org Unsubscribe: https://lists.onap.org/g/onap-discuss/unsub [arch...@mail-archive.com] -=-=-=-=-=-=-=-=-=-=-=-