Hi, >From the logs we can see that the synchronizations fails because the simulator >rejects the PUT of the second policy.
Fault code 400 is returned from the NearRT Simulator (using the OSC A1 API) when either: - the policy type is missing - the json is corrupt - there is another policy instance with the exact same contents To give more help we would need the policy type definitions and the policy data for the different instances. -=-=-=-=-=-=-=-=-=-=-=- Links: You receive all messages sent to this group. View/Reply Online (#23580): https://lists.onap.org/g/onap-discuss/message/23580 Mute This Topic: https://lists.onap.org/mt/85895124/21656 Mute #ccsdk:https://lists.onap.org/g/onap-discuss/mutehashtag/ccsdk Mute #a1:https://lists.onap.org/g/onap-discuss/mutehashtag/a1 Group Owner: [email protected] Unsubscribe: https://lists.onap.org/g/onap-discuss/unsub [[email protected]] -=-=-=-=-=-=-=-=-=-=-=-