Hi,

>From the logs we can see that the synchronizations fails because the simulator 
>rejects the PUT of the second policy.

Fault code 400 is returned from the NearRT Simulator (using the OSC A1 API) 
when either:

- the policy type is missing
- the json is corrupt
- there is another policy instance with the exact same contents

To give more help we would need the policy type definitions and the policy data 
for the different instances.


-=-=-=-=-=-=-=-=-=-=-=-