Hi Sipos,

this sounds like https://osmocom.org/issues/1756

You need to either revert f1a7b8fc6651f92a8b7f3f27b7ca05d07f4e44e0 in osmo-pcu
or add this to your pcu config:

pcu
 two-phase-access

Normally, whether to use two phase access is decided on the fly, but this
option enforces two-phase-access for every assignment -- and incidentally works
around the unknown bug.

This issue has been sitting there for some time now, and though adding the
WAIT_ASSIGN state makes sense, we've still not resolved the bug hidden within.
https://gerrit.osmocom.org/218

~Neels

-- 
- Neels Hofmeyr <[email protected]>          http://www.sysmocom.de/
=======================================================================
* sysmocom - systems for mobile communications GmbH
* Alt-Moabit 93
* 10559 Berlin, Germany
* Sitz / Registered office: Berlin, HRB 134158 B
* Geschäftsführer / Managing Directors: Harald Welte

Attachment: signature.asc
Description: Digital signature

Reply via email to