Hi Neels, > pcu > two-phase-access
Thanks for this, it "solved" the problem, the PDP context is active now. Will put a note on the wiki. Regards, Csaba ----- Eredeti üzenet ----- Feladó: "Neels Hofmeyr" <[email protected]> Címzett: "Sipos Csaba" <[email protected]> Másolatot kap: "OpenBSC Mailing List" <[email protected]> Elküldött üzenetek: Csütörtök, 2016. Szeptember 8. 13:44:49 Tárgy: Re: PRACH fails Hi Sipos, this sounds like https://osmocom.org/issues/1756 You need to either revert f1a7b8fc6651f92a8b7f3f27b7ca05d07f4e44e0 in osmo-pcu or add this to your pcu config: pcu two-phase-access Normally, whether to use two phase access is decided on the fly, but this option enforces two-phase-access for every assignment -- and incidentally works around the unknown bug. This issue has been sitting there for some time now, and though adding the WAIT_ASSIGN state makes sense, we've still not resolved the bug hidden within. https://gerrit.osmocom.org/218 ~Neels -- - Neels Hofmeyr <[email protected]> http://www.sysmocom.de/ ======================================================================= * sysmocom - systems for mobile communications GmbH * Alt-Moabit 93 * 10559 Berlin, Germany * Sitz / Registered office: Berlin, HRB 134158 B * Geschäftsführer / Managing Directors: Harald Welte