On 08/11/2010 20:02, Williamtfgoossen at cs.com wrote:
> In a message dated 8-11-2010 15:38:26 W. Europe Standard Time, 
> thomas.beale at oceaninformatics.com writes:
>> I have been asking HL7 since 2003 or so to show a clean model of any 
>> of the following in RIM or CDA structures:
>>
>> 2 or 3 sample Apgar
>> standard 3 sample GTT (glucose tolerance test) with patient state
>> ICU vital sign time series
>
>
> Tom,
>
> these are available since about that time in HL7 space. However, they 
> where not balloted yet.
> *
> *

yes I have seen the HL7 models for these things. They are really poor 
(nothing to do with the people doing them; the formalism just doesn't 
support modelling them easily).

- thomas