I've never understood the usefulness of that attribute: Seems strange to populate an attribute that will end up in data with a value that could provoke misunderstandings
El lun., 24 sept. 2018 19:23, Ian McNicoll <i...@freshehr.com> escribió: > Hi Diego, > > Does DV_DURATION not inherit magnitude_status as a separate attribute from > the RM? > > > https://www.openehr.org/releases/trunk/UML/#Architecture___18_1_83e026d_1433773264460_352968_7042 > > Not sure it would work in archetyping constraint but in data it > would/should just be > > value: "P24H" > magnitude_status: "<" > > Ian > > Dr Ian McNicoll > mobile +44 (0)775 209 7859 > office +44 (0)1536 414994 > skype: ianmcnicoll > email: i...@freshehr.com > twitter: @ianmcnicoll > > > Co-Chair, openEHR Foundation ian.mcnic...@openehr.org > Director, freshEHR Clinical Informatics Ltd. > Director, HANDIHealth CIC > Hon. Senior Research Associate, CHIME, UCL > > > On Mon, 24 Sep 2018 at 17:08, Diego Boscá <yamp...@gmail.com> wrote: > >> Yeah, it is supported in 1.4. However, I'm not sure that that Durations >> are the way to go here, as all the duration is constraint as string, which >> means string lists or regex in best case scenario, which IMO makes pretty >> difficult to represent the "<" or ">". Personally I would go with an >> alternative of dv_quantity, as a single one with range is impossible to be >> created if they don't share the same units. When validating, only one of >> the alternatives needs to be valid, thus complying with the "or" >> >> >> >> El lun., 24 sept. 2018 a las 17:39, Pieter Bos (<pieter....@nedap.com>) >> escribió: >> >>> Not sure if this is already in the RM version you use and not sure if >>> ADL 1.4 supports this, but can this be a DV_INTERVAL of DV_DURATION? >>> >>> Regards, >>> >>> Pieter Bos >>> >>> Op 24 sep. 2018 14:42 schreef "Bakke, Silje Ljosland" < >>> silje.ljosland.ba...@nasjonalikt.no>: >>> >>> Hi, >>> >>> >>> >>> I’ve got a use case where we need to represent a time duration (of a >>> symptom), which can be for example <24H or >3M. Is it possible to represent >>> this using the DV_DURATION data type, like you can do with DV_QUANTITY and >>> magnitude_status? If not, what should we do? >>> >>> >>> >>> Kind regards, >>> Silje Ljosland Bakke >>> >>> >>> >>> Information Architect, RN >>> >>> Coordinator, National Editorial Board for Archetypes >>> Nasjonal IKT HF, Norway >>> >>> Tel. +47 40203298 >>> >>> Web: http://arketyper.no<http://arketyper.no/> / Twitter: @arketyper_no< >>> https://twitter.com/arketyper_no> >>> >>> >>> >>> _______________________________________________ >>> openEHR-technical mailing list >>> openEHR-technical@lists.openehr.org >>> >>> http://lists.openehr.org/mailman/listinfo/openehr-technical_lists.openehr.org >>> >> >> >> -- >> >> [image: VeraTech for Health SL] <https://htmlsig.com/t/000001C268PZ> >> >> [image: Twitter] <https://htmlsig.com/t/000001C47QQH> [image: LinkedIn] >> <https://htmlsig.com/t/000001C4DPJG> [image: Maps] >> <https://htmlsig.com/t/000001BZTWS7> >> >> Diego Boscá Tomás / Senior developer >> diebo...@veratech.es >> yamp...@gmail.com >> >> VeraTech for Health SL >> +34 654604676 <+34%20654604676> >> www.veratech.es >> >> La información contenida en este mensaje y/o archivo(s) adjunto(s), >> enviada desde VERATECH FOR HEALTH, SL, es confidencial/privilegiada y está >> destinada a ser leída sólo por la(s) persona(s) a la(s) que va dirigida. Le >> recordamos que sus datos han sido incorporados en el sistema de tratamiento >> de VERATECH FOR HEALTH, SL y que siempre y cuando se cumplan los requisitos >> exigidos por la normativa, usted podrá ejercer sus derechos de acceso, >> rectificación, limitación de tratamiento, supresión, portabilidad y >> oposición/revocación, en los términos que establece la normativa vigente en >> materia de protección de datos, dirigiendo su petición a Avda Puerto 237, >> 1º, pta 1 - 46011 Valencia o bien a través de correo electrónico >> d...@veratech.es >> >> Si usted lee este mensaje y no es el destinatario señalado, el empleado o >> el agente responsable de entregar el mensaje al destinatario, o ha recibido >> esta comunicación por error, le informamos que está totalmente prohibida, y >> puede ser ilegal, cualquier divulgación, distribución o reproducción de >> esta comunicación, y le rogamos que nos lo notifique inmediatamente y nos >> devuelva el mensaje original a la dirección arriba mencionada. Gracias >> _______________________________________________ >> openEHR-technical mailing list >> openEHR-technical@lists.openehr.org >> >> http://lists.openehr.org/mailman/listinfo/openehr-technical_lists.openehr.org >> > _______________________________________________ > openEHR-technical mailing list > openEHR-technical@lists.openehr.org > > http://lists.openehr.org/mailman/listinfo/openehr-technical_lists.openehr.org >
_______________________________________________ openEHR-technical mailing list openEHR-technical@lists.openehr.org http://lists.openehr.org/mailman/listinfo/openehr-technical_lists.openehr.org