But the meaning is for this attribute is to be be used in measures like lab result to express things that are probably barely measurable, not to express that in modelling time the other defined constraint is meant to be the upper (or lower) part of a range
El lun., 24 sept. 2018 a las 20:49, Ian McNicoll (<i...@freshehr.com>) escribió: > Hi Diego, > > We have certainly had to use it in some lab test integrations. I would > normally agree that it might be risky to carry this kind of modifier as a > separate attribute, which could easily be missed in queries, but these are > gnerally imprecise values (as in Silje's use-case) or out-of-range on an > analyser where I think the non-modified value is robably a safe proxy for > the modified one. So, in this case I think it is safe. > > Ian > Dr Ian McNicoll > mobile +44 (0)775 209 7859 > office +44 (0)1536 414994 > skype: ianmcnicoll > email: i...@freshehr.com > twitter: @ianmcnicoll > > > Co-Chair, openEHR Foundation ian.mcnic...@openehr.org > Director, freshEHR Clinical Informatics Ltd. > Director, HANDIHealth CIC > Hon. Senior Research Associate, CHIME, UCL > > > On Mon, 24 Sep 2018 at 19:30, Diego Boscá <yamp...@gmail.com> wrote: > >> yeah, I can see to be useful for that, but seems weird to constraint it >> in any way >> >> El lun., 24 sept. 2018 a las 20:29, Thomas Beale (< >> thomas.be...@openehr.org>) escribió: >> >>> It was added to the RM years ago to support quantities in lab results, >>> which are sometimes of the form <X, >Y etc. If I had my time again, I >>> would have moved the date/time types out a bit so they did not inherit >>> this attribute. Usually it is Void. >>> >>> - thomas >>> >>> >>> >>> _______________________________________________ >>> openEHR-technical mailing list >>> openEHR-technical@lists.openehr.org >>> >>> http://lists.openehr.org/mailman/listinfo/openehr-technical_lists.openehr.org >>> >> >> >> -- >> >> [image: VeraTech for Health SL] <https://htmlsig.com/t/000001C268PZ> >> >> [image: Twitter] <https://htmlsig.com/t/000001C47QQH> [image: LinkedIn] >> <https://htmlsig.com/t/000001C4DPJG> [image: Maps] >> <https://htmlsig.com/t/000001BZTWS7> >> >> Diego Boscá Tomás / Senior developer >> diebo...@veratech.es >> yamp...@gmail.com >> >> VeraTech for Health SL >> +34 654604676 <+34%20654604676> >> www.veratech.es >> >> La información contenida en este mensaje y/o archivo(s) adjunto(s), >> enviada desde VERATECH FOR HEALTH, SL, es confidencial/privilegiada y está >> destinada a ser leída sólo por la(s) persona(s) a la(s) que va dirigida. Le >> recordamos que sus datos han sido incorporados en el sistema de tratamiento >> de VERATECH FOR HEALTH, SL y que siempre y cuando se cumplan los requisitos >> exigidos por la normativa, usted podrá ejercer sus derechos de acceso, >> rectificación, limitación de tratamiento, supresión, portabilidad y >> oposición/revocación, en los términos que establece la normativa vigente en >> materia de protección de datos, dirigiendo su petición a Avda Puerto 237, >> 1º, pta 1 - 46011 Valencia o bien a través de correo electrónico >> d...@veratech.es >> >> Si usted lee este mensaje y no es el destinatario señalado, el empleado o >> el agente responsable de entregar el mensaje al destinatario, o ha recibido >> esta comunicación por error, le informamos que está totalmente prohibida, y >> puede ser ilegal, cualquier divulgación, distribución o reproducción de >> esta comunicación, y le rogamos que nos lo notifique inmediatamente y nos >> devuelva el mensaje original a la dirección arriba mencionada. Gracias >> _______________________________________________ >> openEHR-technical mailing list >> openEHR-technical@lists.openehr.org >> >> http://lists.openehr.org/mailman/listinfo/openehr-technical_lists.openehr.org >> > _______________________________________________ > openEHR-technical mailing list > openEHR-technical@lists.openehr.org > > http://lists.openehr.org/mailman/listinfo/openehr-technical_lists.openehr.org > -- [image: VeraTech for Health SL] <https://htmlsig.com/t/000001C268PZ> [image: Twitter] <https://htmlsig.com/t/000001C47QQH> [image: LinkedIn] <https://htmlsig.com/t/000001C4DPJG> [image: Maps] <https://htmlsig.com/t/000001BZTWS7> Diego Boscá Tomás / Senior developer diebo...@veratech.es yamp...@gmail.com VeraTech for Health SL +34 654604676 <+34%20654604676> www.veratech.es La información contenida en este mensaje y/o archivo(s) adjunto(s), enviada desde VERATECH FOR HEALTH, SL, es confidencial/privilegiada y está destinada a ser leída sólo por la(s) persona(s) a la(s) que va dirigida. Le recordamos que sus datos han sido incorporados en el sistema de tratamiento de VERATECH FOR HEALTH, SL y que siempre y cuando se cumplan los requisitos exigidos por la normativa, usted podrá ejercer sus derechos de acceso, rectificación, limitación de tratamiento, supresión, portabilidad y oposición/revocación, en los términos que establece la normativa vigente en materia de protección de datos, dirigiendo su petición a Avda Puerto 237, 1º, pta 1 - 46011 Valencia o bien a través de correo electrónico d...@veratech.es Si usted lee este mensaje y no es el destinatario señalado, el empleado o el agente responsable de entregar el mensaje al destinatario, o ha recibido esta comunicación por error, le informamos que está totalmente prohibida, y puede ser ilegal, cualquier divulgación, distribución o reproducción de esta comunicación, y le rogamos que nos lo notifique inmediatamente y nos devuelva el mensaje original a la dirección arriba mencionada. Gracias
_______________________________________________ openEHR-technical mailing list openEHR-technical@lists.openehr.org http://lists.openehr.org/mailman/listinfo/openehr-technical_lists.openehr.org