Thanks! Good to know.

On Thursday, March 3, 2016, Chris Grivas <chgriv...@gmail.com> wrote:

>
> I am using openflow plugin (helium) design and the delay only happens with
> cpqd. The notifications do NOT delay when I use openvswitch. There is also
> NO delay with either switch when I use openflowplugin-Ii.
>
> Regards,
> Chris
>
> On 04 Mar 2016, at 01:45, Abhijit Kumbhare <abhijitk...@gmail.com
> <javascript:_e(%7B%7D,'cvml','abhijitk...@gmail.com');>> wrote:
>
> Thanks Luis. But I think his message (unexpected rpc response in
> GetFeaturesOutput) seems to be different than the bug (which has unexpected
> rpc response in BarrierOutput). Also he seems to be having issue with the
> delay in the switch notifications.
>
> Chris - are you running the openflow-plugin-li (Lithium design) or just
> openflow plugin (Helium design)?
>
> On Thu, Mar 3, 2016 at 3:04 PM, Luis Gomez <ece...@gmail.com
> <javascript:_e(%7B%7D,'cvml','ece...@gmail.com');>> wrote:
>
>> I think that is not this bug but this one:
>> https://bugs.opendaylight.org/show_bug.cgi?id=4614. Please make sure
>> your switch properly handles xid.
>>
>> BR/Luis
>>
>> On Mar 3, 2016, at 3:28 AM, Chris Grivas <chgriv...@gmail.com
>> <javascript:_e(%7B%7D,'cvml','chgriv...@gmail.com');>> wrote:
>>
>> Hi all,
>>
>> I am trying to move from lithium to beryllium.
>> Using beryllium, when a mininet topology using OF 1.3 switches gets 
>> connected to the controller the following warnings appear in the log for 
>> every switch in the topology:
>>
>> 2016-03-02 11:45:50,405 | WARN  | entLoopGroup-7-2 | ConnectionAdapterImpl   
>>          | 173 - org.opendaylight.openflowjava.openflow-protocol-impl - 
>> 0.7.0.SNAPSHOT | received unexpected rpc response: RpcResultKey 
>> [xid=3613138056, 
>> outputClazz=org.opendaylight.yang.gen.v1.urn.opendaylight.openflow.protocol.rev130731.GetFeaturesOutput]
>>
>> This seems to be related to the bug #5090 which can be found here: 
>> https://bugs.opendaylight.org/show_bug.cgi?id=5090
>>
>> However, this is not my main problem. The main problem is that the 
>> notifications about the OpenFlow switches arrive with a *delay*.
>> It takes about 30-50 seconds after the above warnings are logged in order 
>> the controller to receive the new switch notifications.
>>
>> Can I configure someway the notifications not to be delayed? Is it some 
>> possible bug that causes the above?
>>
>>
>> Thank you in advance,
>>
>> Chris
>>
>> _______________________________________________
>> openflowplugin-dev mailing list
>> openflowplugin-dev@lists.opendaylight.org
>> <javascript:_e(%7B%7D,'cvml','openflowplugin-dev@lists.opendaylight.org');>
>> https://lists.opendaylight.org/mailman/listinfo/openflowplugin-dev
>>
>>
>>
>> _______________________________________________
>> openflowplugin-dev mailing list
>> openflowplugin-dev@lists.opendaylight.org
>> <javascript:_e(%7B%7D,'cvml','openflowplugin-dev@lists.opendaylight.org');>
>> https://lists.opendaylight.org/mailman/listinfo/openflowplugin-dev
>>
>>
>
_______________________________________________
openflowplugin-dev mailing list
openflowplugin-dev@lists.opendaylight.org
https://lists.opendaylight.org/mailman/listinfo/openflowplugin-dev

Reply via email to