Sorry for spamming, but the versions in my previous message is incorrect.
Please ignore the parenthesis.

Chris

2016-03-04 9:43 GMT+02:00 Chris Grivas <[email protected]>:

> Update/edit:
> The delay happens in both openflowplugin-li and openflowplugin.
>
> One can easily reproduce the delay by installing just
> odl-openflowplugin-flow-services-rest feature and trying to connect a
> topology to it using cpqd (version 2.4.9). I inspect the topology through
> restconf/operational/network-topology:network-topology and I also inspect
> the log where the notifications delay.
>
> I do not think that it is something in the soft switch as it was working
> as it is supposed to, using stable/Lithium release. Something has to have
> changed in the way notifications are handled in the stable/Beryllium I
> would say.
>
> Any ideas on what may be causing the delay?
>
> 2016-03-04 9:11 GMT+02:00 Abhijit Kumbhare <[email protected]>:
>
>> Thanks! Good to know.
>>
>>
>> On Thursday, March 3, 2016, Chris Grivas <[email protected]> wrote:
>>
>>>
>>> I am using openflow plugin (helium) design and the delay only happens
>>> with cpqd. The notifications do NOT delay when I use openvswitch. There is
>>> also NO delay with either switch when I use openflowplugin-Ii.
>>>
>>> Regards,
>>> Chris
>>>
>>> On 04 Mar 2016, at 01:45, Abhijit Kumbhare <[email protected]>
>>> wrote:
>>>
>>> Thanks Luis. But I think his message (unexpected rpc response in
>>> GetFeaturesOutput) seems to be different than the bug (which has unexpected
>>> rpc response in BarrierOutput). Also he seems to be having issue with the
>>> delay in the switch notifications.
>>>
>>> Chris - are you running the openflow-plugin-li (Lithium design) or just
>>> openflow plugin (Helium design)?
>>>
>>> On Thu, Mar 3, 2016 at 3:04 PM, Luis Gomez <[email protected]> wrote:
>>>
>>>> I think that is not this bug but this one:
>>>> https://bugs.opendaylight.org/show_bug.cgi?id=4614. Please make sure
>>>> your switch properly handles xid.
>>>>
>>>> BR/Luis
>>>>
>>>> On Mar 3, 2016, at 3:28 AM, Chris Grivas <[email protected]> wrote:
>>>>
>>>> Hi all,
>>>>
>>>> I am trying to move from lithium to beryllium.
>>>> Using beryllium, when a mininet topology using OF 1.3 switches gets 
>>>> connected to the controller the following warnings appear in the log for 
>>>> every switch in the topology:
>>>>
>>>> 2016-03-02 11:45:50,405 | WARN  | entLoopGroup-7-2 | ConnectionAdapterImpl 
>>>>            | 173 - org.opendaylight.openflowjava.openflow-protocol-impl - 
>>>> 0.7.0.SNAPSHOT | received unexpected rpc response: RpcResultKey 
>>>> [xid=3613138056, 
>>>> outputClazz=org.opendaylight.yang.gen.v1.urn.opendaylight.openflow.protocol.rev130731.GetFeaturesOutput]
>>>>
>>>> This seems to be related to the bug #5090 which can be found here: 
>>>> https://bugs.opendaylight.org/show_bug.cgi?id=5090
>>>>
>>>> However, this is not my main problem. The main problem is that the 
>>>> notifications about the OpenFlow switches arrive with a *delay*.
>>>> It takes about 30-50 seconds after the above warnings are logged in order 
>>>> the controller to receive the new switch notifications.
>>>>
>>>> Can I configure someway the notifications not to be delayed? Is it some 
>>>> possible bug that causes the above?
>>>>
>>>>
>>>> Thank you in advance,
>>>>
>>>> Chris
>>>>
>>>> _______________________________________________
>>>> openflowplugin-dev mailing list
>>>> [email protected]
>>>> https://lists.opendaylight.org/mailman/listinfo/openflowplugin-dev
>>>>
>>>>
>>>>
>>>> _______________________________________________
>>>> openflowplugin-dev mailing list
>>>> [email protected]
>>>> https://lists.opendaylight.org/mailman/listinfo/openflowplugin-dev
>>>>
>>>>
>>>
>
_______________________________________________
openflowplugin-dev mailing list
[email protected]
https://lists.opendaylight.org/mailman/listinfo/openflowplugin-dev

Reply via email to