Cool :) > On Sep 1, 2016, at 7:28 PM, Tai, Hideyuki <[email protected]> wrote: > > Hi Luis, > > Thank you for sharing the great information. > > The information matches with my investigation. > > I've written the outcome of my investigation so far into the bug report. > https://bugs.opendaylight.org/show_bug.cgi?id=6595#c2 > > I think the OpenFlow plugin failed to process port status message, because it > failed to get a WriteTransaction. > And, the OpenFlow plugin failed to get the WriteTransaction, because it was > before it started the service as MASTER for the siwtch. > > Best Regards, > Hideyuki Tai > ________________________________________ > From: [email protected] > <[email protected]> on behalf of Luis Gomez > <[email protected]> > Sent: Thursday, September 1, 2016 7:17 PM > To: Shuva Jyoti Kar > Cc: [email protected] > Subject: Re: [openflowplugin-dev] Blocking bugs > > In the case of cluster the port status ERROR seem to happen just after a > member becomes SLAVE for a device: > > https://logs.opendaylight.org/releng/jenkins092/openflowplugin-csit-3node-clustering-only-boron/606/archives/odl3_karaf.log.gz > > While in VTN Manger the issue seems to happen because of longer Master > selection the first time switch connects to controller: > > 2016-08-31 23:18:01,788 | INFO | entLoopGroup-5-2 | ConnectionAdapterImpl > | 173 - org.opendaylight.openflowjava.openflow-protocol-impl - > 0.8.0.Boron-RC2 | Hello received / branch > 2016-08-31 23:18:02,428 | WARN | entLoopGroup-5-3 | DeviceContextImpl > | 183 - org.opendaylight.openflowplugin.impl - 0.3.0.Boron-RC2 | > Error processing port status message: > 2016-08-31 23:18:02,553 | INFO | lt-dispatcher-20 | LifecycleServiceImpl > | 183 - org.opendaylight.openflowplugin.impl - 0.3.0.Boron-RC2 | > ========== Start-up clustering MASTER services for node openflow:1 was > SUCCESSFUL ========== > > In successive switch connections the Master resolution is very fast: > > 2016-08-31 23:27:28,551 | INFO | entLoopGroup-5-6 | ConnectionAdapterImpl > | 173 - org.opendaylight.openflowjava.openflow-protocol-impl - > 0.8.0.Boron-RC2 | Hello received / branch > 2016-08-31 23:27:28,582 | INFO | lt-dispatcher-21 | LifecycleServiceImpl > | 183 - org.opendaylight.openflowplugin.impl - 0.3.0.Boron-RC2 | > ========== Start-up clustering MASTER services for node openflow:1 was > SUCCESSFUL ========== > > BR/Luis > > >> On Sep 1, 2016, at 10:33 AM, Luis Gomez <[email protected]> wrote: >> >> Sure, will do that today. >> >> >>> On Sep 1, 2016, at 10:11 AM, Shuva Jyoti Kar <[email protected]> >>> wrote: >>> >>> Luis/Venkat, >>> >>> Have pushed a gerrit get more information on the port whose status is being >>> missed: >>> https://git.opendaylight.org/gerrit/#/c/45024/ >>> >>> Please try it out with this and share the logs to analyse the failure to >>> process the port status message. >>> We need to establish that the tx chain is activated while we are trying to >>> update the port status >>> >>> Thanks >>> Shuva >>> >>> From: Luis Gomez [mailto:[email protected]] >>> Sent: Thursday, September 01, 2016 2:40 PM >>> To: Shuva Jyoti Kar >>> Cc: Venkatrangan G - ERS, HCL Tech; Andrej Leitner; >>> [email protected] >>> Subject: Re: [openflowplugin-dev] Blocking bugs >>> >>> FYI the "Error processing port status message" is not seen very often in >>> openflow test suites for 1 node but it is very present in 3 node cluster >>> test: >>> >>> >>> https://logs.opendaylight.org/releng/jenkins092/openflowplugin-csit-3node-clustering-only-boron/604/archives/odl1_karaf.log.gz >>> >>> >>> BR/Luis >>> >>> >>> >>> >>> On Sep 1, 2016, at 1:21 AM, Shuva Jyoti Kar <[email protected]> >>> wrote: >>> >>> Venkat, >>> >>> I see add flow failing with “Device reported error type BADACTION code >>> BADSETARGUMENT”, “Device disconnected” and >>> “java.util.concurrent.CancellationException: Task was cancelled” , which >>> are genuine. >>> Do we know what is the flow that is being rejected as a BADACTION , or why >>> is there a flow push when the device is disconnected or why was the task >>> cancelled ? >>> >>> Thanks >>> Shuva >>> >>> From: Venkatrangan G - ERS, HCL Tech [mailto:[email protected]] >>> Sent: Thursday, September 01, 2016 1:14 PM >>> To: Shuva Jyoti Kar; Luis Gomez; Andrej Leitner >>> Cc: [email protected] >>> Subject: RE: [openflowplugin-dev] Blocking bugs >>> >>> Shuva, >>> It fails very frequently since 23rd this month. Every time it fails all >>> the ping tests in OF10 fail, which makes it unusable for Openflow 1.0. >>> Ref: >>> https://logs.opendaylight.org/releng/jenkins092/vtn-csit-1node-coordinator-only-boron/195/archives/karaf.log.gz >>> >>> Remove Flows RPC has resulted in a failure, Add Flow has resulted in a >>> failure, Statistics has resulted in a failure, Due to these failures the >>> flow entries were not installed. >>> >>> >>> Regards, >>> Venkat G >>> >>> From: Shuva Jyoti Kar [mailto:[email protected]] >>> Sent: Wednesday, August 31, 2016 11:31 PM >>> To: Venkatrangan G - ERS, HCL Tech <[email protected]>; Luis Gomez >>> <[email protected]>; Andrej Leitner <[email protected]> >>> Cc: [email protected] >>> Subject: RE: [openflowplugin-dev] Blocking bugs >>> >>> Venkat, >>> >>> Could you please explain your last statement? Does it fail sporadically or >>> consistently ? >>> >>> Also the statement for bug 6595 states “The latest regression runs for VTN >>> CSIT jobs reports failure >>> in normal flow installation when testing with OF 1.0 switches” >>> Is that correct since the flow installation fails genuinely because of >>> errors. >>> >>> Please let us know >>> >>> Thanks >>> Shuva >>> >>> From: Venkatrangan G - ERS, HCL Tech [mailto:[email protected]] >>> Sent: Thursday, September 01, 2016 11:57 AM >>> To: Shuva Jyoti Kar; Luis Gomez; Andrej Leitner >>> Cc: [email protected] >>> Subject: RE: [openflowplugin-dev] Blocking bugs >>> >>> Shuva, >>> >>> We also see that the Port Statistics RPC has failed, which results in VTN >>> concluding that ports are DOWN. VTN is a reactive implementation, hence VTN >>> does not install entries considering the egress port is DOWN. >>> The tests are not failing in every run, but every time it fails, OF1.0 >>> failures are observed. >>> >>> >>> Regards, >>> Venkat G >>> >>> From: [email protected] >>> [mailto:[email protected]] On Behalf Of >>> Shuva Jyoti Kar >>> Sent: Wednesday, August 31, 2016 11:18 PM >>> To: Luis Gomez <[email protected]>; Andrej Leitner >>> <[email protected]> >>> Cc: [email protected] >>> Subject: Re: [openflowplugin-dev] Blocking bugs >>> >>> Yes, but if I drill into the logs >>> >>> 1) >>> https://logs.opendaylight.org/releng/jenkins092/vtn-csit-1node-coordinator-only-boron/209/archives/karaf.log.gz >>> a. errors=Device disconnected (3times) >>> 2) >>> https://logs.opendaylight.org/releng/jenkins092/vtn-csit-1node-manager-only-boron/637/archives/karaf.log.gz >>> a. errors=Device reported error type BADACTION code BADSETARGUMENT(19 >>> times) >>> b. errors=Device disconnected (10 times) >>> c. reason java.util.concurrent.CancellationException: Task was >>> cancelled(5 times) >>> >>> If you search for SalFlowServiceImpl. >>> We do have 0f1.0 TCs for flowprovisioning , are those passing ? If yes then >>> probably , vtn might need to drill down further >>> >>> Thanks >>> Shuva >>> >>> >>> >>> From: [email protected] >>> [mailto:[email protected]] On Behalf Of >>> Luis Gomez >>> Sent: Thursday, September 01, 2016 11:35 AM >>> To: Andrej Leitner >>> Cc: [email protected] >>> Subject: Re: [openflowplugin-dev] Blocking bugs >>> >>> The bug 6654 is happening sporadically in our system test but you can >>> reproduce it very quickly if you stop and start mininet with no delay for >>> few times. Thats what I did to confirm the issue. >>> >>> The bug 6595 is blocker because VTN has a regression in its OF10 system >>> test using the new plugin. BTW I also see this exception very often in the >>> openflow system test so it would be good to fix it for the Boron release. >>> >>> BR/Luis >>> >>> >>> >>> On Aug 31, 2016, at 8:43 PM, Andrej Leitner <[email protected]> >>> wrote: >>> >>> Hi, >>> I assume 6554 is not fixed yet. I've tried to get into it, but was unable >>> to reproduce it locally. Today is public holiday on Slovakia so will >>> continue on Friday. I don't know 6595, must be something new. >>> From: Abhijit Kumbhare <[email protected]> >>> Sent: Wednesday, August 31, 2016 9:09:54 PM >>> To: [email protected] >>> Subject: [openflowplugin-dev] Blocking bugs >>> >>> Hi folks, >>> >>> We seem to have two blocking bugs - that we should discuss tomorrow if not >>> fixed already: >>> >>> https://bugs.opendaylight.org/show_bug.cgi?id=6554 >>> >>> https://bugs.opendaylight.org/show_bug.cgi?id=6595 >>> >>> Thanks, >>> Abhijit >>> AndrejLeitner >>> Software Developer >>> >>> Sídlo / Mlynské Nivy 56 / 821 05 Bratislava / Slovakia >>> R&D centrum / Janka Kráľa 9 / 974 01 Banská Bystrica / Slovakia >>> / [email protected] >>> reception: +421 2 206 65 114 / www.pantheon.sk >>> >>> >>> _______________________________________________ >>> openflowplugin-dev mailing list >>> [email protected] >>> https://lists.opendaylight.org/mailman/listinfo/openflowplugin-dev >>> >>> >>> >>> ::DISCLAIMER:: >>> ---------------------------------------------------------------------------------------------------------------------------------------------------- >>> The contents of this e-mail and any attachment(s) are confidential and >>> intended for the named recipient(s) only. >>> E-mail transmission is not guaranteed to be secure or error-free as >>> information could be intercepted, corrupted, >>> lost, destroyed, arrive late or incomplete, or may contain viruses in >>> transmission. The e mail and its contents >>> (with or without referred errors) shall therefore not attach any liability >>> on the originator or HCL or its affiliates. >>> Views or opinions, if any, presented in this email are solely those of the >>> author and may not necessarily reflect the >>> views or opinions of HCL or its affiliates. Any form of reproduction, >>> dissemination, copying, disclosure, modification, >>> distribution and / or publication of this message without the prior written >>> consent of authorized representative of >>> HCL is strictly prohibited. If you have received this email in error please >>> delete it and notify the sender immediately. >>> Before opening any email and/or attachments, please check them for viruses >>> and other defects. >>> ---------------------------------------------------------------------------------------------------------------------------------------------------- >> > > _______________________________________________ > openflowplugin-dev mailing list > [email protected] > https://lists.opendaylight.org/mailman/listinfo/openflowplugin-dev
_______________________________________________ openflowplugin-dev mailing list [email protected] https://lists.opendaylight.org/mailman/listinfo/openflowplugin-dev