On Tue, 2008-07-08 at 06:29 +0000, Dan Horák wrote: > Hi, > > one of my colleagues has a question - is it possible to use > ipmi/ipmidirect plugin to access sensor data from a HP blade with ilo2? > He has some success with the ipmitool accessing the data, but when he > tries the hpi* tools then he gets only some error messages.
Dan, Ipmidirect plug-in will not work on HP/ilo2s. HP exports SOAP XML as an external interface for blade management and the OpenHPI OA SOAP plug-in serves that purpose. -- Shuah ------------------------------------------------------------------------- Sponsored by: SourceForge.net Community Choice Awards: VOTE NOW! Studies have shown that voting for your favorite open source project, along with a healthy diet, reduces your potential for chronic lameness and boredom. Vote Now at http://www.sourceforge.net/community/cca08 _______________________________________________ Openhpi-devel mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/openhpi-devel