Hi Preeti,

change in your file: lines 541 and 1618 from WDT_GET to WTD_GET.

There was a minor change in the past to correct the watchdog timer syntax from 
WTD to WDT. But it looks like we've overseen something.
At the moment the old syntax WTD regarding watchdog is for the simulator 
relevant.

Maybe it makes sense you open a ticket for this issue.

Best regards
   Lars


On Tuesday, 8. March 2011 17:38, Preeti Sharma wrote:
> Hi,
> OA_SOAP plugin's specific "HP BladeSystem c-Class to HPI Mapping Developers
> Guide" documents FAN entity path location:
>
> {SYSTEM_CHASSIS,<No.>} {COOLING_UNIT,1} {COOLING_DEVICE,<No.>}{FAN,<No.>}
>
> I made this change in simulation.data. Ran entres command in hpi_shell . I
> don't see FAN in shown entity paths list. I am attaching simulation.data
> with this mail.
>
> Regards,
> Preeti

-- 
-------------------------------