Hi Preeti,
change in your file: lines 541 and 1618 from WDT_GET to WTD_GET.
There was a minor change in the past to correct the watchdog timer syntax from
WTD to WDT. But it looks like we've overseen something.
At the moment the old syntax WTD regarding watchdog is for the simulator
relevant.
Maybe it makes sense you open a ticket for this issue.
Best regards
Lars
On Tuesday, 8. March 2011 17:38, Preeti Sharma wrote:
> Hi,
> OA_SOAP plugin's specific "HP BladeSystem c-Class to HPI Mapping Developers
> Guide" documents FAN entity path location:
>
> {SYSTEM_CHASSIS,<No.>} {COOLING_UNIT,1} {COOLING_DEVICE,<No.>}{FAN,<No.>}
>
> I made this change in simulation.data. Ran entres command in hpi_shell . I
> don't see FAN in shown entity paths list. I am attaching simulation.data
> with this mail.
>
> Regards,
> Preeti
--
-------------------------------
Dipl. Wi.ing.
Lars Wetzel
Uttinger Str. 13
86938 Schondorf a. Ammersee
Tel.: 0179-2096845
Mail: [email protected]
USt-IdNr.: DE181396006
------------------------------------------------------------------------------
What You Don't Know About Data Connectivity CAN Hurt You
This paper provides an overview of data connectivity, details
its effect on application quality, and explores various alternative
solutions. http://p.sf.net/sfu/progress-d2d
_______________________________________________
Openhpi-devel mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/openhpi-devel