Hi, It;s the good news... bad news...
I've got the merged 1.8.0 OpenSM up and running. I have a number of questions (which I'll send separately) but the one main problem I have now is the following: I have a 4x HCA port (1x/4x LinkWidthEnable and Supported) connected via a 1x analyzer connected to a switch (so is 1x LinkWidthActive). OpenSM does not seem to want to bring this port up. It tries once and gives up until the physical link is cycled (cable pull and reinsertion). It does work running over a 4x link with 4x neighbor ports. I see the following: SM side HCA side Set PortInfo (NoStateChange) -> <- GetResp PortInfo (Init) Set PortInfo (Armed) -> <- GetResp PortInfo (Armed) Set PortInfo (Active) -> <- GetResp PortInfo (Init) I didn't track the settings on the switch side neighbor port but assume they mirror this. OpenSM just seems to never try to bring this port active again without some external stimulus. That's the secondary issue. Can you try this ? -- Hal _______________________________________________ openib-general mailing list openib-general@openib.org http://openib.org/mailman/listinfo/openib-general To unsubscribe, please visit http://openib.org/mailman/listinfo/openib-general