http://bugzilla.openmoko.org/cgi-bin/bugzilla/show_bug.cgi?id=79
------- Additional Comments From [EMAIL PROTECTED] 2008-04-13 08:11 ------- Created an attachment (id=587) --> (http://bugzilla.openmoko.org/cgi-bin/bugzilla/attachment.cgi?id=587&action=view) Restore power button functionality after resume operation Per Werner's suggestion, run the PMU interrupt handler immediately after resume to clear/handle any pending interrupts from that device. This appears to resolve the dead-powerbutton-after-resume problem. This is not well-tested; need feedback to see if there are any side-effects or other problems. ------- You are receiving this mail because: ------- You are the assignee for the bug, or are watching the assignee.