http://bugzilla.openmoko.org/cgi-bin/bugzilla/show_bug.cgi?id=79





------- Additional Comments From [EMAIL PROTECTED]  2008-04-13 08:11 -------
Created an attachment (id=587)
 --> 
(http://bugzilla.openmoko.org/cgi-bin/bugzilla/attachment.cgi?id=587&action=view)
Restore power button functionality after resume operation

Per Werner's suggestion, run the PMU interrupt handler immediately after resume
to clear/handle any pending interrupts from that device.  This appears to
resolve the  dead-powerbutton-after-resume problem.  This is not well-tested;
need feedback to see if there are any side-effects or other problems.



------- You are receiving this mail because: -------
You are the assignee for the bug, or are watching the assignee.