Hello,

On Sun, Mar 22, 2015 at 11:36:53PM +0100, Michael Schwingen wrote:
> I started working with an LPC812. Using a ST-Link V2 as SWD interface,
> this seems to work, but I can't get reset working - it seems the reset
> output is always active, so I decided to pull out my bus blaster.

Active as in pulled low? Is that with reset_config srst_only or none?
I think stlinkv2 is known to behave properly in this regard.

> Any hints where to look? Is FT2232+KTLINK or the LPC812 considered stable?

Both are known to work (with ktlink CPLD bitstream from the URL
mentioned in the config file), and you're the first to report an
issue.

-- 
Be free, use free (http://www.gnu.org/philosophy/free-sw.html) software!
mailto:fercer...@gmail.com

------------------------------------------------------------------------------
Dive into the World of Parallel Programming The Go Parallel Website, sponsored
by Intel and developed in partnership with Slashdot Media, is your hub for all
things parallel software development, from weekly thought leadership blogs to
news, videos, case studies, tutorials and more. Take a look and join the 
conversation now. http://goparallel.sourceforge.net/
_______________________________________________
OpenOCD-devel mailing list
OpenOCD-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/openocd-devel

Reply via email to