Hi Tim FWIW we (Microchip/Microsemi) have a similar situation with our SmartFusion/SmartFusion2 SoC FPGAs which have an FPGA top level TAP and also a hard Cortex-M3 with its own TAP in the MSS (Microcontroller Sub-system). The former has to be negotiated and a special command sent before the latter can be accessed. The attached target script shows how we manage this. Perhaps (some of) this might be relevant to your situation?
Hope this helps Regards Tommy ________________________________ From: Tim Newsome <[email protected]> Sent: Monday 6 January 2020 20:05 To: OpenOCD ML <[email protected]> Subject: [OpenOCD-devel] handle targets that are inaccessible when connecting I have a RISC-V target with 2 TAP controllers chained together. The first controller connects to a core that's always accessible. The second controller connects to a core that's only accessible after the first core has done some setup, which (at least initially) requires the debugger. If I just configure both of those and connect then OpenOCD errors out because examine() fails on the core behind the second controller because it's not powered up yet. How can I change the code to make this case work? Is there an example for some other target? Tim
microsemi-cortex-m3.cfg
Description: microsemi-cortex-m3.cfg
_______________________________________________ OpenOCD-devel mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/openocd-devel