Hi Tim

FWIW we (Microchip/Microsemi) have a similar situation with our 
SmartFusion/SmartFusion2 SoC FPGAs which have an FPGA top level TAP and also a 
hard Cortex-M3 with its own TAP in the MSS (Microcontroller Sub-system). The 
former has to be negotiated and a special command sent before the latter can be 
accessed. The attached target script shows how we manage this. Perhaps (some 
of) this might be relevant to your situation?

Hope this helps
Regards
Tommy

________________________________
From: Tim Newsome <[email protected]>
Sent: Monday 6 January 2020 20:05
To: OpenOCD ML <[email protected]>
Subject: [OpenOCD-devel] handle targets that are inaccessible when connecting

I have a RISC-V target with 2 TAP controllers chained together. The first 
controller connects to a core that's always accessible. The second controller 
connects to a core that's only accessible after the first core has done some 
setup, which (at least initially) requires the debugger.

If I just configure both of those and connect then OpenOCD errors out because 
examine() fails on the core behind the second controller because it's not 
powered up yet. How can I change the code to make this case work? Is there an 
example for some other target?

Tim

Attachment: microsemi-cortex-m3.cfg
Description: microsemi-cortex-m3.cfg