Ack, code review only/Thanks HansN
-----Original Message-----
From: Gary Lee
Sent: den 11 november 2016 06:47
To: Gary Lee <[email protected]>; [email protected]; Minh Hon
Chau <[email protected]>; Hans Nordebäck <[email protected]>;
[email protected]; Long Hong Buu Nguyen <[email protected]>
Cc: [email protected]
Subject: [PATCH 1 of 1] amfnd: send node_up even if led_state is not green
osaf/services/saf/amf/amfnd/di.cc | 5 ++---
1 files changed, 2 insertions(+), 3 deletions(-)
if amfd restarts before set_leds is received by amfnd, then amfnd will not send
node_up. amfnd should send node_up even if led state is not green.
diff --git a/osaf/services/saf/amf/amfnd/di.cc
b/osaf/services/saf/amf/amfnd/di.cc
--- a/osaf/services/saf/amf/amfnd/di.cc
+++ b/osaf/services/saf/amf/amfnd/di.cc
@@ -562,13 +562,12 @@ uint32_t avnd_evt_mds_avd_up_evh(AVND_CB
*/
if (evt->info.mds.i_change == NCSMDS_NEW_ACTIVE &&
cb->is_avd_down) {
if (cb->led_state == AVND_LED_STATE_GREEN) {
- LOG_NO("Sending node up due to
NCSMDS_NEW_ACTIVE");
-
// node_up, sync sisu, compcsi info to AVND for
recovery
avnd_sync_sisu(cb);
avnd_sync_csicomp(cb);
- avnd_send_node_up_msg();
}
+ LOG_NO("Sending node up due to NCSMDS_NEW_ACTIVE");
+ avnd_send_node_up_msg();
}
cb->is_avd_down = false;
}
------------------------------------------------------------------------------