On Friday 10 April 2009 16:19:28 Mike DeMarco wrote:
> You should only see a very little performace hit when using zones.
> Maybe 1 or 2 %. Are you using exclusive NIC to move the TCP stack
> down into the zone? Have you tuned the zone for mysql?
> What disk do you have the zone OS on?
> Do you have enough memory and swap?
>

update, there's some connectivity problem: we have packet losses in 
the range 4-20%. The server is using  4 aggregated gb ethernet cards.
I was thinking to detach each of the 4 cables in turn to identify the 
possibly faulty connection. Is it a good idea? Is there any command
I can use to identify the broken links? 

[r...@nodo1: ~ ]$ dladm show-link
bge0            type: non-vlan  mtu: 1500       device: bge0
bge1            type: non-vlan  mtu: 1500       device: bge1
e1000g0         type: non-vlan  mtu: 1500       device: e1000g0
e1000g1         type: non-vlan  mtu: 1500       device: e1000g1
e1000g2         type: non-vlan  mtu: 1500       device: e1000g2
e1000g3         type: non-vlan  mtu: 1500       device: e1000g3
aggr1           type: non-vlan  mtu: 1500       aggregation: key 1

[r...@nodo1: ~ ]$ dladm show-aggr
key: 1 (0x0001) policy: L4      address: 0:e:c:7e:1f:a4 (auto)
           device       address                 speed           duplex  
link    state
           e1000g0      0:e:c:7e:1f:a4    1000  Mbps    full    up      
attached
           e1000g1      0:e:c:7e:1f:a5    1000  Mbps    full    up      
attached
           e1000g2      0:e:c:7e:1f:a6    1000  Mbps    full    up      
attached
           bge1         0:9:3d:12:67:dd   1000  Mbps    full    up      
attached


_______________________________________________
opensolaris-discuss mailing list
[email protected]

Reply via email to