Hi, In the alertmanager.yml file you should have a receiver for Vitrage. Please verify that it includes "send_resolved: true". This is required for Prometheus to notify Vitrage when an alarm is resolved.
The full Vitrage receiver definition should be: - name: *<receiver name>* webhook_configs: - url: *<vitrage event url>* # example: 'http://127.0.0.1:8999/v1/event' send_resolved: true http_config: basic_auth: username: *<an admin user known to keystone >* password: *<user’s password>* Hope it helps, Ifat On Tue, Oct 2, 2018 at 7:51 AM Won <wjst...@gmail.com> wrote: > I have some problems with Prometheus alarms in vitrage. > I receive a list of alarms from the Prometheus alarm manager well, but the > alarm does not disappear when the problem(alarm) is resolved. The alarm > that came once in both the alarm list and the entity graph does not > disappear in vitrage. The alarm sent by zabbix disappears when alarm > solved, I wonder how to clear the Prometheus alarm from vitrage and how to > update the alarm automatically like zabbix. > thank you. > __________________________________________________________________________ > OpenStack Development Mailing List (not for usage questions) > Unsubscribe: openstack-dev-requ...@lists.openstack.org?subject:unsubscribe > http://lists.openstack.org/cgi-bin/mailman/listinfo/openstack-dev >
__________________________________________________________________________ OpenStack Development Mailing List (not for usage questions) Unsubscribe: openstack-dev-requ...@lists.openstack.org?subject:unsubscribe http://lists.openstack.org/cgi-bin/mailman/listinfo/openstack-dev