Thanks Matthias for educating me. As there is no universal solution to this issue, I will check if launch instance page strategy will work out for this case.

Regards,
Saravanan KR

On 11/04/2015 03:47 PM, Matthias Runge wrote:
On 04/11/15 09:25, Saravanan KR wrote:

There may be multiple solutions:
1) Waiting for the synchronous and then respond
2) Do not trigger page refresh and respond with Operation in progress
3) If there is a mechanism to know delete in progress, do not list the
interface

To decide on the solution, it is important to know how 202 responses
should be handled. Can anyone can help with understanding?
Asynchronous operations are handled in horizon as synchronous
operations. To illustrate that: launch an instance, you'll get
immediately a feedback ("launch instance issued").
But, you don't get a status feedback directly. Horizon pulls nova api
for status updates via ajax calls.

So: there is no solution yet for this. You could duplicate the same
update strategy as in launch instance (on instances page), create a
volume (on volumes table), etc.

In ideal case, one would use something like a message bus to get
notified on changes.

Matthias



__________________________________________________________________________
OpenStack Development Mailing List (not for usage questions)
Unsubscribe: openstack-dev-requ...@lists.openstack.org?subject:unsubscribe
http://lists.openstack.org/cgi-bin/mailman/listinfo/openstack-dev



__________________________________________________________________________
OpenStack Development Mailing List (not for usage questions)
Unsubscribe: openstack-dev-requ...@lists.openstack.org?subject:unsubscribe
http://lists.openstack.org/cgi-bin/mailman/listinfo/openstack-dev

Reply via email to